Graco PR70 Instructions - Parts Manual page 7

Conversion kit
Table of Contents

Advertisement

11. Remove the mounting board from the PR70 frame
as shown in Figure 5.
F
. 5
IG
12. Attach the new FCM mounting board assembly (C)
to the PR70 frame using the fasteners that were
removed in step 10. See Figure 6 below.
F
. 6
IG
3A6225A
C
13. Reattach the FCM base and assembly (B) and the
cable splitter to the new mounting board (C) using
the existing screws that were removed in steps
8-10.
B
D
F
. 7
IG
14. Reattach the air lines to the air fittings (E) on the
new voltage to pressure regulator as shown in Fig-
ure 8.
NOTE: If the current air lines are worn or damaged,
replacement air lines are included in this kit. You can cut
them to fit your needs.
F
. 8
IG
15. If you are using low level sensors, attach the two
cables with the M8 male ends from the terminal strip
(D) on the new assembly to ports 3 and 4 on the
fluid control module. See Figure 7 above and Fig-
ure 3 on page 6.
16. Attach the two cables with the M8 female ends from
the terminal strip on the new assembly to the exist-
ing low level sensor cables.
Installation
Cable Splitter
E
7