Graco PR70 Instructions - Parts Manual page 17

Conversion kit
Table of Contents

Advertisement

NOTE: See the PR70 and PR70V Operation - Maintenance manual 312759 for Optional External Control Interface
instructions.
2
NOTE: Connector #2 is for use
with systems with an Advanced
Display Module only.
NOTE: View shown is looking at
pins on end of cable.
1
NOTE: Connector #1 is for use
with all systems.
NOTE: View shown is looking at
pins on end of cable.
F
. 16: Electric Schematic - Page 4
IG
3A6225A
2
1
5
3
4
Brown
2
1
5
Gray
Black
3
4
Blue
White
Customer Supplied
Dry Contact/Relay
Brown
SHOT SEL - BIT 0
Gray
SHOT SEL - BIT 3
Black
Not Used
Blue
COMMON
White
SHOT SEL - BIT 1
Customer Supplied
Dry Contact/Relay
SHOT REQUEST - INPUT
FAULT OUTPUT
INTERRUPT - CAN - REQ - INPUT
COMMON
READY - OUTPUT
Electrical Schematics
+24 VDC
+24 VDC