iNstaLLatiON MaNUaL
BO800RN
Retrofit housing and retrofit handles
5] WiRiNG
Example N°1: Exit button only (VHLD timer optional)
Exit
Button
Voltage 12Vdc
or 24Vdc
ARD212
Example N°2: Access Control + Exit Button
Access
Control
Unit
Voltage 12Vdc
or 24Vdc
ARD212
Example N°3: Access Control + Exit Button
Access
Control
Unit
Input voltage:
48 V DC*
MAGNETIC LOCK
N°1
MAGNETIC LOCK
N°2
Retrofit housing
or handle
Exit
Button
Retrofit housing
Exit Button
Retrofit housing
5-WaY tERMiNaL stRiP
NON MONitORED vERsiON
+ 12Vdc or 24Vdc positive *
- 12Vdc or 24Vdc negative *
* Voltage: 12Vdc or 24Vdc.
Place the « jumpers » to select 12Vdc or 24Vdc
supply to your magnetic locks
5-WaY tERMiNaL stRiP
MONitORED vERsiON
+
12Vdc or 24Vdc positive *
-
12Vdc or 24Vdc negative *
NC Contact «Normally Closed»
COM Common
NO Contact «Normally Open»
* Voltage: 12Vdc or 24Vdc.
Place the « jumpers » to select 12Vdc
or 24Vdc supply to your magnetic locks.
tiME RELaY FOR MaGNEtiC LOCKs (REF: tPv)
Important: When using a timer
in circuit, please make note of the voltage
used and ensure the timer can operate
at the same voltage (example
shows TPV).
MAGNETIC LOCK
N°1
MAGNETIC LOCK
N°2
or handle
MAGNETIC LOCK
N°1
MAGNETIC LOCK
N°2
or handle
Adjustable timer
(0 to 20 seconds)
5-Way terminal strip
– non monitored version
+ 12Vdc or 24Vdc positive *
- 12Vdc or 24Vdc negative *
* Voltage: 12Vdc or 24Vdc.
Place the « jumpers » to select
12Vdc or 24Vdc supply to your
magnetic locks
24 V DC
Input voltage: 48 VDC.
Magnetic locks connected in series.
cdvigroup.com
EN
12Vdc
24Vdc
12Vdc
24Vdc
12Vdc
24Vdc
5