Sample Of Serial Number / Safety Label - Hearth and Home Technologies Quadra-Fire SANTAFEI-C Owner's Manual

Table of Contents

Advertisement

NOTE: Clearances may only be reduced by means approved by the regulatory
authority having jurisdiction
A. Sample of Serial Number / Safety Label
LOCATION: On chain behind right access panel & Behind left access panel
SANTAFEI-C
Report / Rapport:
061-S-77c-6.2
0061PM077E
2020
JAN
2021
MAY
2022
SEPT
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 particulate emission standards at
1.1
g/hr EPA Method
28R and ASTM 2779 using premium wood
Input Rating:
THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. CONSULT THE
OWNER'S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS
WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER'S MANUAL.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Made in China/ Fait Aux Chine
SAMPLE: SERIAL NUMBER LABEL
LOCATION: Behind left access panel.
2
and Welcome to the Quadra-Fire Family
*PSANTAFEI-C*
Serial No. / N° de série
US
BARCODE LABEL
FEB
MAR
APR
JUNE
JULY
AUG
OCT
NOV
DEC
pellets.
30,600
Btu's/hr.
7019-799C
SANTAFEI-C
Report No.
#061-S-77d-6.2
0061PM077E
Electrical Rating: 115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 AMPS.
Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This appliance has been
tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909.
Tested to: ASTM E-1509-2004 and ULC S628-93 Room Heating Pellet Burning Type, (UM) 84-HUD FOR USE ONLY WITH
PELLETIZED WOOD OR SHELLED FIELD CORN FUEL. Do not use any other type of fuel. OMNI-Test Laboratories, Inc. has
determined that this appliance complies with Canadian Standards Association (CSA) B415.1 and Title 40 of the U.S.
Code of Federal Regulations, Part 60, SubPart AAA.OMNI-Test Laboratories Accrediations: The Standards Council of
Canada, the American National Standards Institute, and the U.S. Environmental Protection Agency.
Route power cord away from unit. Do not route cord under or in front of appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm ceramic available
from your dealer.
To start, set thermostat above room temperature, the appliance will light automatically. To shutdown, set thermostat to below room
temperature. For further instruction refer to owner's manual.
KEEP VIEWING AND ASH REMOVAL DOORS TIGHTLY CLOSED DURING OPERATION.
Install and use only in accordance with manufacturer's installation and operating instructions. CONTACT LOCAL BUILDING
OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.
WARNING - FOR MOBILE HOMES: Do not install appliance in a sleeping room. An outside combustion air inlet
must be provided. The structural integrity of the mobile home floor, ceiling and walls must be maintained.
Refer to manufacturer's instructions and local codes for precautions required for passing chimney through a combustible
wall or ceiling. Inspect and clean vent system frequently in accordance with manufacturer's instructions.
Do Not Connect This Unit to a Chimney Serving Another Appliance.
Use a 3" or 4" diameter type "L" or "PL" venting system.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
A
B
C
0 in. Clearance To Exposed Section And Face Trim
Max. Mantel Depth: 12 in. (305mm)
MANTEL
B
C
A
E
F
DO NOT REMOVE THIS LABEL
SAMPLE: CLEARANCE TO COMBUSTIBLES LABEL
LOCATION: On chain behind right access panel
7019-802H
!
SAFETY LABEL
R
*PSANTAFEI-C*
Input Rating:
30,600
BTU/HR.
PREVENT HOUSE FIRES
AS A BUILT-IN UNIT
C
D
A Top of Hopper
B
B Side of Hopper
C Back of Hopper
D Vent Pipe to Combustible Top/Rear Vent 3.0 in. 76mm
Masonry or Zero Clearance
A Insert side to combustible side wall
Face Trim
B Insert top to mantel
C Insert top to max. 2.25 in. to top face trim
D Insert side to max. 2.25 in. to side face trim
E Hearth extension to from door opening - front 6 in .
D
F Hearth extension from side of door opening
*When constructing floor protection for your pellet appliance,
any parts or materials used, must be non-combustible.
352 Mountain House Road,
Halifax, PA 17032
www.quadrafire.com
Top Vent
2.0 in. 51mm
Rear Vent
2.5 in. 64mm
Top/Rear Vent 2.0 in. 51mm
Top/Rear Vent 2.5 in. 64mm
16 in.
406mm
12 in.
305mm
4.75 in.
121mm
10 in.
254mm
152mm
6 in.
152mm
7019-800C
04/21