Technical Data; Operator Information - Electrolux Smart Service Manual

Boiling pan
Table of Contents

Advertisement

Warning!
Overheating
In the event of overheating, a buzzer is activated and the
following text appears in the display:
ELEMENT
OVERHEATED
In the event of a fault in the element sensor, the heat is
switched off.
Switch off the pan by:
Pressing On/Off
ting protection. The display goes out.
Wait for 5 seconds!
Press On/Off
. The display is lit.
If the warning remains lit
Check the water level in the pressure vessel. (See
'Filling pressure vessel with water' in the installation
instructions.)
If the warning remains lit, call in a trained engineer.
The water level in the vessel should be checked at
least once per quarter. (See 'Filling pressure vessel
with water' in the installation instructions.)
Safety valve
Fig. 1
A. Safety valve
B. Manometer
C. Steam trap
D. Metering tap (for accredited
body in the event of an inspection)
A well-functioning safety valve is an extremely important
part of the pan's safety system.
The safety valve (Fig. 1 pos. A) opens automatically if
the pressure exceeds 1.5 bar.
Switch off the pan immediately and call in a trained eng-
ineer.
Warning!
If the safety valve (Fig. 1 pos. A) opens, hot steam will
blow out from the valve.
Regular checks of the safety valve should be car-
ried out by trained personnel.
We recommend: once per week.
4
(see Fig. 3) to reset the overhea-
Checking the safety valve
A:1
Fig. 2
Lift the handle so that the steam has free passage
through the safety valve, Fig.2 pos.A:1 and Fig.2 pos.
A:2.
If you cannot get the valve to open (blow) it should be
replaced immediately. Call in a trained engineer.
Manometer
Manometer Fig. 1 pos.B, measures the steam pressure.
Must not exceed 1.5 bar.
If the indicator goes into the red field
Switch off the pan immediately and call in a trained eng-
ineer.
*
For a correct pressure reading, lift up the green cap
on the manometer.
NOTE! The green cap must normally be pressed down as
the pan will be tipped.
Steam trap
The steam trap Fig. 1 pos.C, releases the cold air in
the steam generator when starting the pan. When
the water in the steam generator starts to boil and
hot steam starts to stream out, the steam trap clo-
ses automatically.

Technical data

The rating plate
A rating plate, which contains the pan's product number,
is located on the side of the pan column and in the swit-
ching room, as well as on the Manufacturer's Declaration
that accompanies the machine on delivery.
Noise level: < 70 dB

Operator information

Before working with the product, the operator must
- be fully aware of how to operate and maintain the mach-
ine.
- locate each warning sign and understand their purpo-
se.
- read the safety instructions and warning texts ex-
tremely carefully.
Read the General Instructions.