5 Getting started
In compliance with DTU 68.3, the installer/contractor must:
▪
Clearly explain the reasons for ventilating (Indoor Air Quality),
▪
Explain the technical aspects of the appliance,
▪
Explain the operation of the appliance,
▪
Give specific information on the appliance (always in operation during the intended periods,
do not obstruct the air inlets and outlets, clearance under doors, etc.),
▪
Remind the user of the care and maintenance instructions given in the installation and
operating manuals and that the ventilation must never be stopped
▪
Give the user the operating manual.
6 Care
6.1
Filter
The VMI® PULSE'R Prestige unit is equipped with:
-
Pollens filter
-
Or Fine particle filter
-
Or Pollen, fine particle & odour filter - 3 in 1
(For 3V or 4V installations, the VMI® PULSE'R Prestige unit is also equipped with a G4 sleeve filter)
To ensure optimum air quality and correct functioning of the VMI® unit, the filter must be regularly
changed (Minimum once a year).
Refer to step 12 of the assembly instructions when changing the URBAN VMI® filter
Changing the filter
▪
Order a new filter from VENTILAIRSEC.
▪
Access the VMI® unit.
▪
Manually unscrew the 2 plastic head screws on the filter compartment.
▪
Remove the old filter.
WARNING: do not insert anything in the machine apart from the new filter.
▪
Insert the new filter.
o For a G4 filter: the blue part of the filter must be facing the outside of the machine.
o For an F7 filter: the tab on the filter must be pointing towards the outside of the VMI®
unit.
The new filter must be quickly inserted after the old one is removed.
▪
Screw down the 2 plastic head screws.
▪
Reset the filter counter (number of days used) on the remote control (see 6.2 Resetting the
filter counter, Care section).