Check Type
Check Mode
1. Check the connections for the power cable.
2. Check the voltage of the power outlet.
3.Check the wires of the Main PBA power part.
- Measure the voltage between the
Power Check
None
4. Check the DC voltage of the Main PBA.
Check the DC voltage of the Main PBA.
Measure the voltage between pin 1 (PINK) and pin 3 (BLUE)of the
main PBA CN6 connector
●
Main-PBA DC
None
●
Voltage Check
Checking Method
● Normal: AC 120V
pink wire and blue wire
● Normal: AC 120V
Normal (Door Close): 0V
Normal (Door Open): 11.4V to 12.6V
- Reconnect the power cable.
- Connect to a 120V power source.
- Faulty: Check and replace the wires of the power part.
- Check voltage
of CN01.
- See "Main PBA DC voltage Check".
Check voltage:11.4V to 12.6V
Corrective actions
Troubleshooting_37