7. THE OUTPUT CONNECTOR FUNCTION

The output connectors can be used for a possible connection of a device designed for
monitoring or controlling the supply activity.
IN/OUT INTERFACE is intended for connection to protective hardware systems;
RS232 connector can be used for communication purposes via RS232 interface in
MODBUS RTU protocol.
LAN connector can be used for communication purposes via ETHERNET interface in
MODBUS TCP protocol.
(Modbus Application Protocol V1.1b3)
7.1.

Pin layout of DB9 IN/OUT Interface connector

Interlock couple wires are open / short inputs. Short shall sustain at least 5 mA, open will
present a 12V voltage difference.
Alarm couple wires are open / short outputs. They can be read with a maximum voltage of
24 Vdc and a maximum current of 500 mA.
th
2020
M.HIST.0138.23 R1
Page 19 of 28
October, 06