  • Page 1 USER MANUAL NEG POWER MINI NEG Pump Controller SAES Getters S.p.A. – Italy www.saesgroup.com 2020 M.HIST.0138.23 R1 October, 06 UDOC – CONTROLLED COPY...
  • Page 2 The NEG POWER MINI - NEG Pump Controller power supply serves for operating the NEG (Non Evaporable Getters) pumps. It is designed to be used indoor in laboratory conditions. WARNING After transportation, the device has to be left idle without mains voltage for at least 3 hours at the ambient temperature.
  • Page 3: Table Of Contents

    2.4. The front panel of the unit ..............6 2.5. The rear panel of the unit ..............6 2.6. NEG POWER MINI Dimensions and Weight ........7 2.7. Supplied accessories ............... 7 INSTALLATION ..................8 3.1. Rack mounting ................. 8 3.2.
  • Page 4: Application

    NEG POWER MINI can work in the low range of power with the smallest SAES NEG pumps requiring low values of voltage / current / power with a precision around ± 0.1 V.
  • Page 5: Main Features

    2.2. Electronic circuit features NEG POWER MINI is a switching power supply, with an adjustable voltage output from 0 to 35V. The instrument receives mains voltage (110÷240 VAC, 50÷60 Hz), converts it to DC voltage and supplies the getter pump by means of a microprocessor-based electronic control card.
  • Page 6: The Front Panel Of The Unit

    2.4. The front panel of the unit 1. Alphanumeric display 2. MENU/ENTER button to edit the output parameters and to enter the setup menu to reduce the selected value / scroll down in the menu to increment the selected value / scroll up in the menu 5.
  • Page 7: Neg Power Mini Dimensions And Weight

     NEG POWER MINI weight 1.5 kg 2.7. Supplied accessories The following accessories are provided with NEG POWER MINI: Mains power cable with C16 plug and Schuko plug DB9 plug with PIN to bypass Interlock connections 2020 M.HIST.0138.23 R1 Page 7 of 28...
  • Page 8: Installation

    Insert the instrument in the appropriate space (19” rack 3U according to DIN 41494 standard). Fix the NEG POWER MINI front panel on the rack with four screws. ATTENTION: the instrument cannot be used in potentially flammable or explosive areas.
  • Page 9: Usage

    4. USAGE NEG POWER MINI has an alphanumeric display and four buttons for the local control; it is also possible to control the NEG POWER MINI by the SAES remote control software or by a customer remote command sent in Modbus communication protocol ATTENTION: Before starting to heat the getter pump, check it is under high vacuum level.
  • Page 10 START/STOP is not enabled while editing parameters. When you turn off and turn on NEG POWER MINI, the last settings and used parameters are presented and you can use them again pressing start button without any other change.
  • Page 11: Setting Menu

    With a long press on MENU/ENTER it is possible to enter in the pages to configure the instrument parameters. The pictures show the default parameters of NEG POWER MINI. The first (read only) page shows the software version, the hardware version and the MAC address.
  • Page 12: Maximum Allowed Pump Temperature

    Third page shows Modbus RTU parameters for Modbus over RS232 (DB9 plug). A short pressing on MENU/ENTER activates editing of the first field and moves to the next field, arrow keys change parameter values. After editing the last parameter (Slave) the next pressing on MENU/ENTER ends editing.
  • Page 13: Abnormal Situation And Alarm Notification

    If a pen drive with FAT32 formatting is inserted in the USB port, the instrument automatically logs the parameters during the run phase. An “L” is shown to indicate that log is being recorded. The log file is a text file organized in four columns: as described in the first line, the columns are: time from the start, output voltage, output current, pump temperature.
  • Page 14: Pump Open Alarm

    It indicates that the electrical setting is too high for that pump model. Please, check on the pump manual the recommended voltage setting for your pump model and your pump installation configuration, reduce the voltage setting in order to try again and contact SAES GETTERS S.p.A. for any assistance you need.
  • Page 15: Vmon - Under Voltage - Over Voltage

    Other possible alarm situations are VMON or UNDER VOLTAGE or OVER VOLTAGE. These notifications indicate that there are some problems with the internal circuit and/or with the internal reference voltage levels. Please, contact SAES GETTERS S.p.A. for assistance. 2020 M.HIST.0138.23 R1...
  • Page 16: Recommended Settings

    Voltage level for the correct heating In the manual of each SAES pump you can find detailed instruction on how to operate your NEG pump in the best way, the optimal target temperature and electrical conditions to reach it in all different configurations where the pump can be installed;...
  • Page 17 In the following table, for the example, the temperature and the corresponding voltage current and power parameter settings are reported for activation and conditioning of the most popular SAES getter pumps, like the CapaciTorr and the NEXTorr families, without jacket.
  • Page 18: Slow Heating

    Heating without automatic stop Some applications require special getter pumps (HV) that work when the getter material is hot. NEG POWER MINI can be used to keep these pumps hot giving them the necessary power continuously. To do this, t_hold = is used.
  • Page 19: The Output Connector Function

    7. THE OUTPUT CONNECTOR FUNCTION The output connectors can be used for a possible connection of a device designed for monitoring or controlling the supply activity. IN/OUT INTERFACE is intended for connection to protective hardware systems; RS232 connector can be used for communication purposes via RS232 interface in MODBUS RTU protocol.
  • Page 20: Electrical Specifications

    In case of dust contamination it can be cleaned by means of a vacuum cleaner. For repair the supply should be shipped back to Saes Group S.p.A.. 2020 M.HIST.0138.23 R1...
  • Page 21: Product Configurations And Accessories

    10. PRODUCT CONFIGURATIONS AND ACCESSORIES Configurations and accessories are given in the following section: 10.1. NEG POWER MINI configurations and accessories: Product description Code Note NEG POWER MINI 3B0110 Controller for NEG Pumps Main Input Cable 3B0338 Main cable with IEC 10 A plug and Schuko...
  • Page 22: Instruction For Instrument Disposal

    INSTRUCTION FOR INSTRUMENT DISPOSAL The instrument disposal has to be carried out in compliance with the user’s country applicable regulations. The information below is issued in compliance with the regulations as set out by the 2012/19/EU directive (Waste Electrical and Electronic Equipment). The instrument contains materials which may endanger the environment and it’s not allowed to dispose it with unsorted urban waste.
  • Page 23: Warranty Conditions

    This warranty shall only apply to the BUYER and may not be assigned. During the term of the warranty set forth above, SAES will promptly repair the Products which for their features can be repaired and which do not conform to the specifications and which BUYER returns to SAES at the address provided.
  • Page 24: Service

    13. SERVICE For a request of return of the component contact a SAES Customer Service and will receive a Return Merchandise Authorization (RMA) number. SAES S.p.A. can not accept any instrument which contains radioactivity or contamination of hazards: biological, toxic, reactive, corrosive, explosive or flammable. If this requirement present a problem call SAES Customer Service to discuss alternatives solutions.
  • Page 25: Appendix A: Supply Cables

    APPENDIX A: Supply cables GP 50-2F For the GP 50 pump and pumps not equipped with an electrical connector use the output supply cable supply shown in figure: Brown REAR VIEW OF CONNECTOR Blue Yellow/Green Blue Yellow/Green Brown TO GETTER PUMP TO NEG PUMP CONTROLLER CapaciTorr D400-2, CapaciTorr Z400 CapaciTorr HV200 35, CapaciTorr HV200 63...
  • Page 26 CapaciTorr D50, CapaciTorr D100, CapaciTorr D200, NexTorr D100-5, NexTorr D200-5, NexTorr HV 100, NexTorr HV 200, NexTorr Z100, NexTorr Z200, CapaciTorr Z100, CapaciTorr Z200, For these pumps which are equipped with a dedicated electrical connector, use the output supply cable shown in figure: NexTorr D300-5, NexTorr D500-5, NexTorr HV 300, NexTorr Z300 NexTorr D500-StarCell For these pumps which are equipped with a dedicated electrical connector, use the output supply...
  • Page 27 (BLANK PAGE) 2020 M.HIST.0138.23 R1 Page 27 of 28 October, 06...
  • Page 28 SAES GETTERS S.p.A. – Italy www.saesgroup.com This document is property of SAES Group S.p.A The information contained herein is subject to change without notice 2020 M.HIST.0138.23 R1 Page 28 of 28 October, 06...

Table of Contents