AHNET ADDRESS CONFIGURATION

There is an ERT functionality that helps users set-up the AHnet address.
To send AHnet commands to a unit, the user needs to set-up the
AHnet address to individually send the commands. When installing the
unit (monitor, microphone or other device) the user should set-up a
different AHnet address on each unit. The ERT has a utility that helps the
assignation of the AHnet address task.
Please note that this utility it is only available on the devices that have
the LCD screen configuration (ISD). The devices that have AHnet
address rotary switches don't provide this functionality.
To activate this function, activate DIP2 on SETTINGS ERT switches and
turn the unit on. The ERT will periodically send a special AHnet command
to set-up the AHnet address on each unit. When the units receive the
special AHnet address configuration command, the user will hear the
sound of a beep. By pressing the UP button on the device's cover plate,
the unit set-ups a new AHnet address. The configuration is incremental.
The first unit, in which the up button has been pressed, gets the AHnet
address number 1, the second one will get the AHnet address 2, and
so on.