Download Print this page

Commissioning Checklist - Ideal Heating Halo Installation Manual

Heat & system 2-zone extension
Hide thumbs Also See for Halo:

Advertisement

COMMISSIONING CHECKLIST

Description
Use the "Identify" function to confirm successful pairing has
taken place. Short press on the Pair button on the Smart
Interface. Press Pair button again to exit "Identify" function.
Halo is positioned in the homeowners chosen location if desk mounted.
Check RSSI (Received Signal Strength Indication) of the Zigbee
wireless connection via support page on the PRT (access via the
menu).
Check RSSI (Received Signal Strength Indication) of the Zigbee
wireless connection and the Wi-Fi connection via the support
information in the Halo app. (Wi-Fi only)
On the Halo set the mode to AUTO then increase the
temperature to 30°C (repeat using Halo app if applicable).
Note: The boiler will only fire once the zone valve is in the
fully open position.
On the Halo set the heating mode to AUTO then decrease
the temperature to 5°C (repeat using Halo app).
On the Halo set the hot water mode to ON
(repeat using Halo app).
Note: The boiler will only fire once the zone valve is in the
fully open position.
On the Halo set the hot water mode to OFF
(repeat using Halo app).
When both Halo units are set up use this commissioning
checklist to check and complete the install
Zigbee LED on Smart Interface
flashes green
Halo home screen flashes to indicate
successful pairing
Zigbee LED on Smart Wiring Centre
flashes green
Target RSSI between 0 and -65
and text green
Target RSSI between 0 and -65
and text green
Flame icon ON
Heating zone on Smart Wiring Centre OFF
Boiler ON
Boiler LED on Smart Interface ON (Green)
Flame OFF
Heating zone on Smart Wiring Centre OFF
Boiler OFF
Boiler LED on Smart Interface OFF
Hot water ON (icon turns orange)
Hot water zone Smart Wiring Centre ON
Boiler ON
Boiler LED on Smart Interface ON (Green)
Hot water OFF (icon turns white)
Hot water zone Smart Wiring Centre OFF
Boiler OFF
Boiler LED on Smart Interface OFF