Input And Output Signals - Citizen iDP-3310 User Manual

Serial thermal printer
Table of Contents

Advertisement

6.3 Input and Output Signals

6.3.1 Input and Output Signals
(1) Input Signals to the Printer
DATA
: 8-bit parallel signal. (Positive logic)
STB
: Strobe signal to read 8-bit data. (Negative logic)
RESET
: Signal to reset the entire printer (Negative logic) 1m sec more
(2) Output Signals from Printer
ACK
: An 8-bit data request signal. Pulse signal output at the end of the BUSY signal.(Negative
logic)
BUSY
: The signal to indicate BUSY state of the printer. Input new data for "LOW."(Positive logic)
FAULT
: The signal which is made "LOW" when the printer is in alarm state. All the control circuit
inside the printer are stopped at this time.(Negative logic)
SELECT : The signal which is made "HIGH" when the printer is ready to receive the data. (Positive
logic)
(3) Power related signal
GND
: This is the common ground for the circuits.
22
iDP3310 User's Manual
CITIZEN

Advertisement

Table of Contents
loading

Table of Contents