Quick Start - Autogrow IntelliClimate Installation And User Manual

Climate controller
Hide thumbs Also See for IntelliClimate:
Table of Contents

Advertisement

Quick start

This is not a substitute for reading the relevant sections of the manual but is included to
emphasize some important and useful points.
If the growroom is to be operated at high humidity for long periods (e.g. during cutting/rooting
stage) it is preferable to mount the controller outside the growroom. This is easily done as the
growroom sensors are supplied with a long 5m (15ft) cable. If required, this can be replaced with
a longer cable. Data cable such as CAT5 computer network cable should be used in this situation
This should be Stranded cable to avoid breakages.
The IntelliClimate Kit comes with one EnviroSensor unit (measuring temperature, relative
humidity, light and CO
). A second optional EnviroSensor unit may be connected which is useful
2
in larger growrooms (> 10m x 10m). Control will normally be based on the average readings from
the two sensors, but should one sensor fail, control will automatically revert to the working
sensor.
Ver 6.0 IntelliClimate Installation Guide (21 August 2020)
Copyright©2020 Autogrow Systems Ltd
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IntelliClimate and is the answer not in the manual?

Related Products for Autogrow IntelliClimate

Table of Contents