INSTALLATION INSTRUCTIONS
CTS602 HMI
BY NILAN
Combi 302 Polar Top (English)
Version 3.01 - 25.03.2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CTS602 HMI and is the answer not in the manual?

Questions and answers

Summary of Contents for nilan CTS602 HMI

  • Page 1 INSTALLATION INSTRUCTIONS CTS602 HMI BY NILAN Combi 302 Polar Top (English) Version 3.01 - 25.03.2019...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety Power supply ....................................................Heat pump ventilation ................................................Disposal ..........................................................Ventilation unit ..................................................... Heatpump ......................................................General information Introduction ........................................................General information prior to installation ......................................Final inspection ......................................................Ventilation Combi unit ................................................Unit type ........................................................... Product description ................................................
  • Page 3 Combi 302 Polar Top (English) BY NILAN Ventilation installation Duct system ......................................................Legislation ...................................................... Ducts ........................................................Unit .......................................................... Extract air ......................................................Supply air ......................................................Roof stacks ....................................................Balancing ........................................................Important information ..............................................Balancing spouts ..................................................Pressure fall diagram .................................................
  • Page 4: Power Supply

    The responsibility for maintaining the heat pump lies with the owner/user. Disposal Ventilation unit Nilan’s units consist mainly of recyclable materials. They must, therefore, not be mixed with household waste, but must be delivered to your local recycling center for disposal.
  • Page 5: General Information Introduction

    Instructions can be downloaded from Nilan’s website: http://www.nilan.dk/en-gb/frontpage/download If you have questions regarding installation of the unit after having read the instructions, contact your nearest supplier of Nilan products, who can be found on www.nilan.dk/en-gb/frontpage/download/ dealers. The purpose of these instructions is to advice the installer on correct installation and maintenance of the unit.
  • Page 6: Final Inspection

    Final inspection Ventilation Combi unit How to set the unit This list is intended for the installer to get an overview of what settings to use in consultation with the user or the builder. Function Settings Setting of frequency of filter change Days: What level constitutes basic ventilation Level:...
  • Page 7: Unit Type

    Combi 302 Polar Top (English) BY NILAN Unit type Product description Combi 302 Polar Top is a combined passive and active heat recovery unit with cooling function. The unit is designed for airflows up to 430 m /h at 100 Pa external duct pressure.
  • Page 8: Overview Of Temperature Sensors

    Overview of temperature sensors Temperature sensors in the unit Temperature sensors outside the unit T1: Outdoor air T7: Supply air after heating element (accessory) T2: Supply air T9: On heating element (accessory) T4: Extract air after heat exchanger T5: Condenser T6: Evaporator T10: Extract air...
  • Page 9: Dimensional Drawing

    Combi 302 Polar Top (English) BY NILAN Dimensional drawing All dimensions are in mm. Connections: 1. Fresh air (outdoor air) 2. Supply air 3. Eztract air 4. Discharge air 5. Condensate drain...
  • Page 10: Functional Diagram

    Functional diagram Heating function Cooling function Connections Automation 1. Outdoor air T1: Outdoor air sensor 2. Supply air T2: Supply air sensor 3. Extract air T4: Discharge sensor 4. Discharge air T5: Condenser sensor 5. Condensate drain T6: Evaporator sensor 6.
  • Page 11: Accessories

    If the water trap dries out, air will be sucked into the unit and condensate water will not be able to drain. This will cause water damage. Nilan’s water trap contains a ball that ensures that no air is sucked into the unit and that condensate water can drain freely.
  • Page 12: Vibration Absorbers

    To make it easy to service the unit in the future, we recommend that you fit a flexible connection between the unit and the duct system. Nilan's flexible sound damper absorbs sounds effectively from both the duct system and from roof stacks.
  • Page 13: Set Up

    Combi 302 Polar Top (English) BY NILAN Set up Installation Positioning of the unit ATTENTION When positioning the unit, you should always consider future services and maintenance. It must be easy to change filters, and it must, for instance, be possible to remove the heat exchanger, and to replace fans or other components.
  • Page 14: Electrical Installation Electrical Connections

    Electrical installation Electrical connections Safety ATTENTION All work must be carried out by qualified persons and in compliance with existing legislation and regulations. ATTENTION It is important that the power is off, if you do work to the electrical components of the unit. It is important to check that wires are not damaged or squeezed during connection and use.
  • Page 15: Control Panel

    Combi 302 Polar Top (English) BY NILAN Control panel HMI User panel The user panel is supplied with 1½ m cable. Connect the panel to the CTS602 control system in the unit using a CAT.5e cable (max. length 50 m).
  • Page 16: Wall Bracket

    Wall bracket Mount the HMI panel on the wall using the integrated wall bracket. The panel should be visible so it is possible to change settings and to monitor warnings or alarms regarding operation. The wall bracket is located at the back of Mount the bracket on the wall using 2 Click the RJ12 plug into place at the the panel.
  • Page 17: Electrical Connections Unit

    Combi 302 Polar Top (English) BY NILAN Electrical connections unit Power supply CAUTION The power supply, including a safety switch, must be installed by an authorized electrician. A power cable for connection to a power socket is included. It is important that the unit is earthed.
  • Page 18: Electrical Connection Accessories

    Electrical connection accessories Connection to user selection and Modbus User selection: Connection to user selection can be used, for instance, for controlling a cooker hood. This happens via a potential free contact in the cooker hood that sends a signal to the unit, which, in turn, increases ventilation when the cooker hood is on.
  • Page 19: Electrical After-Heating Element

    Combi 302 Polar Top (English) BY NILAN Electrical after-heating element An after-heating element is necessary if you want to control the supply air temperature. The electrical after-heating element can be purchased for installation in the supply air duct. The required sensor and connectors for the unit are included.
  • Page 20: External Heating Control System

    External heating control system The unit can control an external heat supply, such as electric radiators or an underfloor heating system. The unit monitors the room temperature and blocks the external heat supply when heating is not needed. If, through ventilation alone, the unit is unable to heat the room to the temperature you want, the external heat supply will be released until the room temperature has increased to the desired level.
  • Page 21: Plumbing Installation Condensate Drain

    INFO Nilan offers a water trap with a ball. The ball ensures that no air blows into the unit through the condensate drain if the water trap dries out. This ensures that water in the condensate tray can...
  • Page 22: Connection Bottom

    Connection bottom Ø20 mm min. 50 mm Ø20 mm min. 170 mm min. 50 mm Connection of water trap generally Connecting Nilan’s water trap with ball...
  • Page 23: Plumbing Connection - Accessories

    Combi 302 Polar Top (English) BY NILAN Plumbing connection - accessories Water trap with ball (option) Connection options with Nilan’s water trap: 1. Water trap with Ø32 mm reducing fitting 2. Reducing fitting for Ø20 mm 3. Reducing fitting for ¾" RG 4.
  • Page 24: Duct System

    Nilan offers flexible Sound Flex tubes that provide a flexible connection between the unit and the duct system, but also reduce the sound transmission from the unit to the duct system.
  • Page 25: Extract Air

    Combi 302 Polar Top (English) BY NILAN Extract air Install exhaust air valves in rooms that generate humidity. Place them strategically where they can extract humidity most effectively. Rooms that generate humidity: • Bathroom • Lavatory • Kitchen • Utility room Supply air Install supply air valves in living areas.
  • Page 26: Balancing

    Balancing Important information ATTENTION To ensure the ventilation system operates optimally, it is important that it is balanced correctly. We recommend that experts do this. It is important to measure the total supply air and the total extract air. The system must have a minimum vacuum, which means it must draw out more air than it blows in.
  • Page 27 Combi 302 Polar Top (English) BY NILAN...
  • Page 28 United Kingdom: S L Services 25 St Leonards Road, Horsham RH13 6EH West Sussex Tlf. +44 (0) 7919 444452 stuart315@aol.com www.nilanuk.com Ireland: Nilan Ireland Ballylahive, Abbeydorney Tlf. +353 (0) 87 9798361 maurice@nilan.ie www.nilanireland.ie Nilan A/S Nilanvej 2 DK-8722 Hedensted Tlf.