Download Print this page

Cisco Catalyst 3560V2-24PS Datasheet page 13

Cisco catalyst 3560v2-24ps: specifications
Hide thumbs Also See for Catalyst 3560V2-24PS:

Advertisement

Power Connectors
Indicators
Dimensions
(H x W x D)
Weight
Environmental Ranges
Acoustic Noise
Mean Time Between
Failure (MTBF)
© 2009 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information.
● Customers can provide power to a switch by using either the internal power supply or the Cisco RPS 2300. The
connectors are located at the back of the switch.
Internal-Power-Supply Connector
● The internal power supply is an autoranging unit.
● The internal power supply supports input voltages between 100 and 240 VAC.
● Use the supplied AC power cord to connect the AC power connector to an AC power outlet.
● Cisco RPS Connector
● The connector offers connection for an optional Cisco RPS 2300 (model PWR-RPS2300) that uses AC input and
supplies DC output to the switch.
● Per-port status LEDs: Link integrity, disabled, activity, speed, full-duplex indications, PoE applied, PoE error, and
PoE disabled indications
● System-status LEDs: System, RPS, link status, link duplex, link speed, and PoE indications
3560V2-24TS
3560V2-48TS
3560V2-24PS
3560V2-48PS
3560V2-24DC
3560V2-24TS
3560V2-48TS
3560V2-24PS
3560V2-48PS
3560V2-24DC
Operating temperature
Storage temperature
Operating altitude
Storage altitude
Operating relative humidity
Storage relative humidity
ISO 7779 & ISO 9296: Bystander positions operating to an ambient temperature of 25° C
Sound Pressure
LpA
(Typical)
3560V2-24TS
41 dB
3560V2-48TS
42 dB
3560V2-24PS
44 dB
3560V2-48PS
45 dB
3560V2-24DC
41 dB
Typical: Noise emission for a typical configuration and load at 25° C
Maximum: Statistical maximum to account for variation in production
3560V2-24TS
3560V2-48TS
3560V2-24PS
3560V2-48PS
3560V2-24DC
Inches
1.73 x 17.46x 11.62
1.73 x 17.46x 11.62
1.73 x 17.46x 11.62
1.73 x 17.46x 11.62
1.73 x 17.46x 11.62
Pounds
8.2
9
10
11
8
Fahrenheit
32 to 113ºF
-13 to 158ºF
Feet
Up to 9,843 ft
Up to 15,000 ft
10 to 85% noncondensing
10 to 85% noncondensing
Sound Power
LpAD
LwA
(Maximum)
(Typical)
44 dB
5.1 B
45 dB
5.2 B
47 dB
5.5 B
48 dB
5.5 B
44 dB
5.2 B
377,260 hours
301,886 hours
275,360 hours
206,041 hours
451,606 hours
Data Sheet
Centimeters
4.4 x 44.3 x 29.5
4.4 x 44.3 x 29.5
4.4 x 44.3 x 29.5
4.4 x 44.3 x 29.5
4.4 x 44.3 x 29.5
Kilograms
3.7
4
4.6
5
3.7
Centigrade
0 to 45ºC
-25 to 70ºC
Meters
Up to 3,000 m
Up to 4,573 m
LwAD
(Maximum)
5.4 B
5.5 B
5.7 B
5.8 B
5.5 B
Page 13 of 20

Advertisement

loading