Preheat [Preheat]; All [All]; Single Channel [Chan [1]]; Dimmer Curve [Curve] - Chauvet TFX-D12 User Manual

Light dimmers
Table of Contents

Advertisement

Preheat [Preheat]

Action
1)
Press the MENU button to enter the setup
menu.
2)
Press the UP and DOWN buttons to scroll
menu items until you reach [Preheat].
3)
Press MENU button to enter the sub-menu.
4)
Press the UP/DOWN buttons to choose
between [All] and [Chan]/Single Channel
mode.
5)
Press MENU to select mode.
A L L [ A l l]
1)
Press UP/DOWN to select the preheat
value between [000%] – [050%] for all
channels.
SINGLE CHANN EL [Chan [ 1]]
1)
In [Chan [1]]/Single Channel mode press
MENU to change between the channel and
its' start address as noted by the cursor.
2)
In [Chan], press UP/DOWN buttons to
select channels 1~12. In [001], press
UP/DOWN buttons to select percentage
[000%-050%].
3)
Press the ESC button to exit and confirm.

Dimmer Curve [Curve]

Action
1)
Press the MENU button to enter the setup
menu.
2)
Press the UP and DOWN buttons to scroll
menu items until you reach [Curve].
3)
Press the MENU button to enter the sub-
menu.
4)
Press UP/DOWN buttons to select from
Linear, Switch & Square dimmer curve.
5)
Press ESC button to exit and confirm.
TFX-D12 User Manual
Preheat
All
All
[005%]
Chan [1]
[050%]
Curve
(Linear)/(Switch)/(Square)
11
Operating Instructions
Chan [1]
[000%]
2004-11-11/11:32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stage dimmer 12 tfx-d12Stage dimmer 12

Table of Contents