EFORE EGIN What is included 1 x Stage Dimmer™ 6 (TFX-D6) Manual Warranty Card Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling.
Product Overview 10A Circuit breaker Standard 19” EIA rack mountable Rear cover panel Front panel I/O Panel TFX-D6 User Manual Forced air cooling Not visible LCD Display DMX Signal Indicator MENU Button UP Button DOWN Button ESC Button BUTTON FUNCTION...
NSTALLATION Mounting The TFX-D6 dimmer packs are designed to be mounted in a standard 19” EIA rack using the two mounting holes on each flange/(ears). The two mounting flanges are designed for securing the dimmer pack to the front rack mounting rails. It is highly recommended that you add support to the rear of the dimmer pack, especially in touring or road case environments.
Input Power SI NG L E-PHASE 1 phase, 3 wire 120/240 VAC, 60 Amps, 50~60Hz T HREE-PHASE 3 phase, 4 wire 120/240 VAC, 20 Amps per phase, 50~60Hz TFX-D6 User Manual Operating Instructions 2005-04-20/11:20...
Upon powering the dimmer, the LCD panel will display the software version presently installed and shortly after, will enter standby mode. Menu Navigation 1 2 3 4 5 6 TFX-D6 User Manual 1 2 3 4 5 6 Dmx fail Curve...
Dmx fail, Curve, Preheat, Dmx addr, and Pha corr. Press the UP and DOWN buttons to scroll menu items. Press ESC to exit the setup menu. TFX-D6 User Manual 1 2 3 4 5 6 1 2 3 4 5 6 Dmx fail Appendix...
Press the UP/DOWN buttons until you reach [Pha corr]. Press MENU to enter the sub-menu. Press UP/DOWN buttons to choose between [Yes] and [No]. Press ESC button to activate. TFX-D6 User Manual Dmx fail Prog08 Dmx fail (Hold) or (Analog) Speed 00.3s...
UP/DOWN buttons to select DMX starting address [001 to 512]. Repeat steps 1 thru 2 to until you have set all 6 channels. Press the ESC button to exit and confirm. TFX-D6 User Manual Dmx addr (Block) or (Single) Dmx addr Block...
1~6. In [001], press UP/DOWN buttons to select percentage [000%-050%]. Repeat steps 1 thru 2 for any additional channel you would like to change. Press the ESC button to exit and confirm. TFX-D6 User Manual Preheat [005%] Chan [1] [050%] Appendix...
XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
Need help?
Do you have a question about the TFX-D6 and is the answer not in the manual?