Panasonic CS-PC12TKF Service Manual page 8

Table of Contents

Advertisement

Model
Height (I/D / O/D)
Dimension
Width (I/D / O/D)
Depth (I/D / O/D)
Weight
Net (I/D / O/D)
Pipe Diameter (Liquid / Gas)
Standard length
Length range (min – max)
I/D & O/D Height different
Additional Gas Amount
Length for Additional Gas
Inner Diameter
Drain Hose
Length
Fin Material
Fin Type
Indoor Heat
Exchanger
Row × Stage × FPI
Size (W × H × L)
Fin Material
Outdoor
Fin Type
Heat
Row × Stage × FPI
Exchanger
Size (W × H × L)
Material
Air Filter
Type
Power Supply
Power Supply Cord
Thermostat
Protection Device
Indoor Operation Range
Outdoor Operation Range
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
Specifications are subjected to change without prior notice for further improvement.
2.
Indoor
Outdoor
mm (inch)
mm (inch)
mm (inch)
kg (lb)
mm (inch)
m (ft)
m (ft)
m (ft)
g/m (oz/ft)
m (ft)
mm
mm
mm
mm
A
Maximum
°C (°F)
Minimum
°C (°F)
Maximum
°C (°F)
Minimum
°C (°F)
CS-PC24TKF
CU-PC24TKF
302 (11-29/32) / 695 (27-3/8)
1102 (43-13/32) / 875 (34-15/32)
244 (9-5/8) / 320 (12-5/8)
12 (26) / 54 (119)
6.35 (1/4) / 15.88 (5/8)
5.0 (16.4)
3 (9.8) ~ 30 (98.4)
20 (65.6)
30 (0.3)
7.5 (24.6)
16.0
650
Aluminium (Pre coated)
Slit Fin
2 × 17 × 17
836 × 357 × 25.4
Aluminium (Blue coated)
Slit Fin
2 × 31 × 17
25.4 × 651 × 866.6:846.6
Polypropelene
One-touch
Indoor
20
-
Mechanical
DRY BULB
32 (89.6)
16 (60.8)
55 (131)
16 (60.8)
8
WET BULB
23 (73.4)
11 (51.8)
31 (87.8)
11 (51.8)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-pc18tkfCs-pc24tkfCu-pc12tkfCu-pc18tkfCu-pc24tkf