Apera LabSen 371 User Manual

Apera LabSen 371 User Manual

Plastic flat ph electrode

Advertisement

LabSen electrochemical sensors are premium pH electrode with manufacturing technology and key
components imported from Switzerland. LabSen 371 plastic flat pH electrode adopts flat membrane
and PTFE junction structure. It is suitable for wet solid and semi-solid surface, such as paper, skin,
textile and leather.
This probe has following features:
 Anti-corrosion POM (Polyoxymethylene) shaft, have good mechanical performance.
 Blue gel inner solution, does not flow and will not cause bubble.
 Long life reference system, has better stability and service life.

1 Technical Data

Measuring Range
Temperature Range
Shaft Material
Membrane Shape
Reference
Junction

Usage and Maintenance

2
Testing surface need to be clean and wet, such as wet the surface of skin or textile by distilled
2.1
water.
Connect BNC plug to the input on the pH meter.
2.2
When measuring, please unscrew the bottle cap, pull out the electrode and rinse it with
2.3
deionized water. After using, please put the electrode back into the bottle and screw tight the
cap.
The electrode's measuring tip should be soaked in the soaking bottle containing certain
2.4
amount of storage solution to keep the membrane hydrated and junction unblocked. Clean the
bottle and replace the storage solution if the storage solution gets turbid and mildewed. The
electrode should never be sinked in pure water or buffer solution for long.
The connector of the electrode should keep clean and dry. If being contaminated, please clean
2.5
it with medical cotton and absolute alcohol and blow dry to prevent the short circuit of the
electrode and slow reaction of electrode.
After 1-year of use, we recommend replacing the electrode to ensure the best accuracy.
2.6

Warranty

3
We warrant this electrode free from defects in material and workmanship and agrees to repair or
replace free of charge, at option of APERA INSTRUMENTS any malfunctioned or damaged product
LabSen 371 Plastic Flat pH Electrode
User Manual
(0 ~ 14) pH
(0 ~ 80) °C
POM
Flat
Long Life
PTFE
Electrolyte
Soaking Solution
Electrode
Dimension
Connector
Cable
Gel
3M KCl
(Ø12×105) mm
BNC
Ø3×1m

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LabSen 371 and is the answer not in the manual?

Questions and answers

Summary of Contents for Apera LabSen 371

  • Page 1 LabSen electrochemical sensors are premium pH electrode with manufacturing technology and key components imported from Switzerland. LabSen 371 plastic flat pH electrode adopts flat membrane and PTFE junction structure. It is suitable for wet solid and semi-solid surface, such as paper, skin, textile and leather.
  • Page 2 APERA INSTRUMENTS for a period of six months. Warranty period is the time limit to provide free service for the products purchased by customers, not the service life of the tester or electrodes. This limited warranty does not cover any damages due to: transportation;...

Table of Contents