Press 't' to display RT Traffic Toggle.
------------ Utilities -------------
Press 'r' or 'R' to Display Dev0 or Dev1 HI-2130 Registers.
Press 'w' for Memory Watch window
Press 'f' Reads J4 connector and FPGA control signals
Press '1' for Register Write
Press '2' for Memory Write
Press '3' RT Mode Code data word reads
Press '4' Master Reset and reinitializes terminals
Press '5' Toggle Dev0 BCENA on/off
Press '6' Toggle Dev1 BCENA on/off
Press '9' Set RT addresses
Press '0' Toggle between User and Demo(default) modes
Press 'M' for menu, or press any valid menu key. >>
The menu commands are very similar to other Holt ADK's such as the ADK-6138, ADK-6130-2 or ADK-6131.
Lower case characters 'a', 'n, 'b', 'c' and 'r' executes commands on the (Dev0) and 'A', 'N', 'B', 'C' and 'R'
executes commands on Dev1. With a -1F card (only one HI-2130) the upper case commands will not be
presented.
Command 'r' and 'R' is used to display system registers names and values on the screen.
Command 'w' displays a memory dump of device memory showing up to 256 words. This is useful for viewing
other areas of memory such as the illegalization tables, control blocks and data buffers.
Repeat steps 1-3: opening a new (second) command shell, invoking:
4.
selecting card #2
.
5. At this point, you will have two windows open, each running the static executable, and each waiting for
command input. This is where the demonstration exercises begin.
Demo exercises using Device 0
Perform the following in command shell 1:
1. This will demonstrate BC transmitting 15 messages and RT1 captures and displays the traffic data.
Commands 'n' or 'N' initializes the BC to transmit 15 messages. To display RT data traffic some additional
commands must first be executed. Five sets of three repeating messages are transmitted by the BC. SA30 is
configured for data loop-back. So the data transmitted to the RT from the first Receive command is loaded
into the same buffer location the RT will reference when transmitting data back to the BC. Just these three
commands verify that both A and B buses are properly communicating with the BC. The data word values
will match the data from the first Receive command.
BC > RT Receive Cmd, SA30, 32 words, BusA:
RT > BC Transmit Cmd, SA30, 32 words, BusB
RT > BC Transmit Cmd, SA30, 32 words, BusA