Installation Step 6

Install the Door Control

Locate the door control within sight of the door at a
minimum height of 5 feet where small children
cannot reach, and away from all moving parts of the
door and door hardware.
The door control is typically attached directly to the
wall. If installing into drywall, drill 5/32" holes and
use the anchors provided. For pre-wired installations
(as in new home construction), it may be mounted to
a standard single gang box. See illustrations.
1. Strip 1/4" of insulation from one end of the bell
wire. Connect wire to the two screw terminals on
the back of the door control: white wire to 2 and
white/red wire to 1.
2. Remove the push bar cover by gently prying off
the top edge with a coin or screwdriver. Fasten
with 6ABx1-1/4" self-tapping screws (standard
installation) or 6-32x1" machine screws (pre-wired
installation) as follows:
• Install bottom screw, allowing 1/8" to protrude
from the wall.
• Position bottom of door control on screw head
and adjust for snug fit.
• Install top screw with care to avoid cracking
plastic housing. Do not overtighten.
3. (For standard wall mount only)
Run the bell wire up wall and across ceiling to
opener. Use insulated staples to secure wire in
several places. Be careful not to pierce wire with a
staple, creating a short.
4. Connect the bell wire to the terminal screws on
the opener panel: white to 2; white/red to 1.
5. After testing, replace the cover by inserting top
tabs and snapping into place.
Note: After installation, the green indicator light
behind the push bar cover will indicate proper
connection.
The automatic light feature will become functional
1-1/2 minutes after power is restored.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Hardware Shown
Actual Size
Dry Wall
Insulated
Anchors
Staples
Screw 6-32x1"
6ABx1-1/4" Screw
Door Control
Do not connect to live electrical wiring. Connect
only to 24 Volt low voltage wires. Connection to
live wires or higher voltage may cause serious
injury from shock, burn or electrocution.
Children operating or playing with a garage
door opener can injure themselves or others.
The garage door could close and cause
serious injury or death. Do not allow children
to operate the push buttons or remote controls.
A moving garage door could injure someone
under it. Activate the opener only when the
door is properly adjusted, you can see it clearly,
and there are no obstructions to door travel.
Outside Keylock Accessory Connections
To opener terminal screws: white to 2; white/red to 1
STANDARD WALL MOUNT
To Replace
Insert Top
Tabs First
Push Bar Cover
Push Bar
2-Conductor
Bell Wire
Door
Control
Terminal
Screws
Lock
Button
Light Button
Right Panel of Opener
18
WARNING
PRE-WIRED INSTALLATION
24 Volt
2-Conductor
Bell Wire
To Replace
Insert Top
Tabs First
Detector
Push Bar Cover
Detector
Switch
ON
OFF
Opener Terminal Screws
1
2
9
7
3
5
KG
Antenna
ON
OFF
Switch
3
1
9
1
7
3
5
KG