Note: Speed 4 (intensive timed)
remains activated for 5 minutes,
after which the hood sets speed 2
automatically
T4. Speed timing
Speed timing is activated by pressing
T4 button, when timing is up the hood
switches off.
Timing is divided as follows:
Speed 1 - 20 minutes (LED L1
flashing)
Speed 2 - 15 minutes (LED L2
flashing)
Speed 3 - 10 minutes (LED L3
flashing)
Intensive speed - 5 minuts (LED L4
flashing)
During timed operation press T2
button and the hood quits the timed
mode and decreases the speed.
Press T3 button and the hood quits
the timed mode and increases the
speed.
Press T4 button and the hood quits
the timed mode maintaining the set
speed.
T5. Filter saturation signal button
– Control and Configuration:
See relevant instructions in the
following paragraphs.
T6. ON/OFF Suction motor: When hood
is on, it switches off at any speed by
pressing button T6.
When the hood is off, it switches on at
Speed 1 by pressing button T6.
Grease filter signal
After 40 hours of operation LED L1 fl ashes.
When such signal appears, carry out grease
fi lter maintenance.
To reset the signal, keep T5 button pressed
for 5". (hood is ON).
The hood gives out a "BEEP" and LED L1
stops fl ashing.
Charcoal fi lter signal
After 160 hours of operation LED L2
fl ashes.
When such signal appears, carry out
charcoal fi lter maintenance.
To reset the signal, keep T5 button pressed
for 5". (hood is ON).
The hood gives out a "BEEP" and LED L2
stops fl ashing.
In case of contemporaneous signalling
of both fi lters, LEDs L1 and L2 fl ash
alternatively.
To reset, carry out the procedure described
above for 2 times.
The fi rst time it resets the charcoal fi lter
signal, the second time it resets the grease
fi lter signal.
The charcoal fi lter signal is not active in the
standard mode.
In case the hood is used in fi lter version it
is necessary to enable the charcoal fi lter
signal.
Activating charcoal fi lter signal:
Set the hood to OFF and press T5 button
for 5".
Once the button has been pressed, the
LEDs related to the fi lter signals currently
active light up.
The hood gives out a "BEEP" and LED L2
fl ashes for 2".
LEDs L1 and L2 remain on for about 2"
before the hood goes back to OFF.
Deactivating charcoal fi lter signal:
Set the hood to OFF and press T5 button
for 5".
Once the button has been pressed, the
LEDs related to the fi lter signals currently
active light up.
The hood gives out a "BEEP" and LED L2
switches off.
LED L1 remain on for about 2" before the
hood goes back to OFF.