Portway No1 Installation And Operating Instructions

Portway No1 Installation And Operating Instructions

Advertisement

INSTALLATION AND OPERATING INSTRUCTIONS
LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER!
All BFM Stoves exceed the safety and performance requirements of European Standards
Intermittent burning solid fuel roomheaters for installation with a single dedicated chimney.
Independent thermal and emissions testing by SGS Environmental BV, Arnhem in 2019, Notified Body No 0608
(With firebox reducer pair fitted)
Minimum safe distance to
I declare that this information is true, these products meet the requirements of Harmonised Standards and are fit for sale. Signed on
behalf of the manufacturer by Glyn Hughes, Design Engineer, at Winster, Derbyshire, England 22. Nov. 2019
Read these instructions! Use only recommended fuels!
This document, when completed by the installer, constitutes part of a 'Hearth Notice' for purposes of Building Law. It must be left with the
householder and placed where it can easily be found.
INSTALLED AT LOCATION:
BY:
EMERGENCY CONTACT:
PRODUCTION NUMBER
Emissions tested and certified to EN16510-1, 2019
Conform to EN 13240:2001+A2 2004,
Fuel
Efficiency
Thermal Output
CO (@13% O2)
NOx
Hydrocarbons CxHy
Mean Flue Temp
combustibles
Smoke Emission
Flue Draught
Other fuels: Anthracite, peat, smokeless
FOR A QUALIFIED INSTALLER, FUEL SUPPLIER or CHIMNEY SWEEP:
UK: The Solid Fuel Association, 7 Swanwick Court, Alfreton, Derbyshire DE55
RoI: Irish Nationwide Fireplace Organisation, 162 Capel Street, Dublin 1
BFM 1, 2, 3 and Inset stoves may be used in smoke control areas when
operated strictly in accordance with these instructions and with Soliftec Smoke
Advice Sheet No1 (www.soliftec.com/smokeadvice.htm), when burning:
UK: Untreated wood logs or authorised smokeless fuels (Exempted from s20 of the
Clean Air Act 1993) RoI: Wood logs, smokeless fuels or peat briquettes, but not
petroleum coke (Control of Atmospheric Pollution Regulations, 1970)
page 1 of 5
No1
No2
Wood logs
77
76
%
5.0
8.0
kW
(3.5)
(5.0)
0.05
0.06
%
97
100
mg.m³
57
76
mg.m³
277
344
°C
80
80
cm
32
26
mg.m³
12
12
Pa
7AS Tel:0845-601-4406 www.solidfuel.co.uk
Tel:01-801-5959 www.fireplace.ie
Solid Fuel Stoves v5. Issued - 22/11/2019 (426)
No.1 & No2 Stove
(Eco 2022 models)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the No1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Portway No1

  • Page 1 BFM 1, 2, 3 and Inset stoves may be used in smoke control areas when operated strictly in accordance with these instructions and with Soliftec Smoke Advice Sheet No1 (www.soliftec.com/smokeadvice.htm), when burning: UK: Untreated wood logs or authorised smokeless fuels (Exempted from s20 of the...
  • Page 2 IN 1830 Charles Portway built a stove to heat his ironmongery shop at Halstead in Essex. It was so good that his neighbours started asking for them. Mr Portway had done something completely new - designed his stoves right from the start to give out the maximum heat from the minimum fuel, so that he is known as "The Founding Father of Energy Efficiency".
  • Page 3 LIVING WITH YOUR STOVE Every fuel, chimney and condition of use is different. Only experience will show which are the best settings for you. LIGHTING If lighting after a period of non-use, do check that the flueways and chimney are completely clear. Empty the ashes.
  • Page 4 Which BFM stove have I got? BFM 'Eco2022' stoves are identified by a perforated 'air bar' across the rear inside of the firebox and a firebox roof panel of vermiculite composite. No1 models are approximately 390mm wide, 500mm (No2) Roof panel (1)
  • Page 5 damp. Use only very dry fuel. CHIMNEY FIRE: In the rare event of deposits inside the chimney OVER-FIRING: It is possible to leave the fire too long with the controls igniting (roaring sound + dense smoke, sparks from chimney) set too high leading to 'over firing', seen as glowing metal parts, immediately close the door, shut all air controls and call the fire excessive chimney temperature and risk of parts failing or chimney brigade.

This manual is also suitable for:

No2

Table of Contents