Installing The Status Led Control Panel For Front Accessed Configuration - Dell EMC PowerEdge XR11 Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge XR11:
Table of Contents

Advertisement

Available languages

Available languages

Figure 104. Removing the status LED control panel for Front Accessed configuration
Next steps
Replace the status LED control panel for Front Accessed
Installing the status LED control panel for Front Accessed
configuration
Prerequisites
NOTE:
For Front Accessed configuration, the status LED control panel is on the rear of the system.
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the air
shrouds.
4.
Remove the processor heat sink
5.
Remove the expansion card riser
NOTE:
If required, remove the backplane power and signal cables.
Steps
1. Align and insert the status LED control panel assembly in the slot on the system.
2. Route the status LED control panel cable through the guide slots in the system and connector on system board.
NOTE:
Route the cable properly to prevent the cable from being pinched or crimped.
3. Using the Phillips 1 screwdriver, tighten the screws that secure the status LED control panel assembly to the system.
NOTE:
Die Zahlen auf dem Bild zeigen nicht die genauen Schritte. Die Zahlen dienen der Darstellung der Sequenz.
configuration.
Safety
instructions.
Before working inside your
module.
1.
system.
Installieren und Entfernen von Systemkomponenten
105

Advertisement

Table of Contents
loading

Table of Contents