Honda EM10000K1 Manual page 44

Table of Contents

Advertisement

dummyhead
dummyhead
OTHER ELECTRICAL
CONTROL BOX REMOVAL/INSTALLATION
OTHER ELECTRICAL
Remove the following:
– Maintenance cover/center beam
(Base shop manual: page 5-2)
– Fuel tank (Base shop manual: page 6-4)
– Air cleaner (Base shop manual: page 6-6)
– Generator end cover (Base shop manual: page 5-2)
Open the harness band (1).
Disconnect the connector (2).
Remove the following:
SH, SKH type:
– tapping screw (5 x 14 mm) (3)/harness band (4)
– two washer-screws (4 x 8 mm) (5)/field winding
terminals (6)
– washer-screw (6 x 12 mm) (7)/ground terminal (8)
– two screws (6 x 8 mm) (9)/spring washers (10)/main
winding terminals (11)
LDH type:
– tapping screw (5 x 14 mm) (3)/harness band (4)
– two washer-screws (4 x 8 mm) (5)/field winding
terminals (6)
– washer-screw (6 x 12 mm) (7)/ground terminal (8)
– three screws (6 x 8 mm) (9)/spring washers (10)/
main winding terminals (11)
Open the harness clip (1) and release the wire harness
(2).
Disconnect the 10P connector (3) and 4P connector (4).
11-2
SH, SKH type:
(6)
(7)
(4)
(5)
(3)
(2)
(9)
(10)
LDH type:
(6)
(7)
(4)
(5)
(3)
(2)
(9)
(10)
(3)
(2)
(8)
(1)
(11)
(8)
(1)
(11)
(4)
(1)

Advertisement