Your RO system has been equipped with quality compression and push on fittings throughout. Any
compression fittings should be hand-tightened and then tightened ¼ turn further with a wrench.
Always use the ferrule and tube stiffener provided for each joint. Check that all fittings are snug, as
they may have loosened in transit.
Completing and securing a push-on connection is simple. First, the tubing should be cut square and
any burrs or rough edges removed. Insert the tube firmly and push until the tube end contacts the
stop. Gently tug the tube backwards to assure a secure connection. To disconnect, pull the tube
while pushing in the collet ring. Fittings may be reconnected over and over again, if necessary. See
figure 2. below.
3.2. Install the Feed Water Supply Connection
1. Inspect the cold water supply line and the condition of the pipe. Ensure that the supply pipe
is in good overall condition and is capable of delivering the system's necessary feed water
flow rate. See Section 8 for specified feed water flow rate requirements.
2. Turn the water supply line to your plumbing OFF.