Download Print this page

Dialight ProSite Installation & Operation Instructions page 5

For ce/rcm

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
Electrical Connections
Bracket Models: F*E******(E/F)****
The terminal block is suitable for multi-
stranded or single core wires. The parameters
can be found in Technical Data.
Push Down Terminal Models: F*E********U**
Push down at the 'cross point', insert wire, and
release.
Conductor Range
0,5-4 mm² [20-12 AWG]
Screw Down Terminal Models: F*E********V**
For input power terminal block, loosen
terminal screw, insert wire, and tighten screw.
Conductor Range
0,5-6 mm² [20-10 AWG]
10 mm [0,39 in.]
For dimming & Dali lines, push down at the
'cross point', insert wire, and release.
Conductor Range
0,5-4 mm² [20-12 AWG]
Slip Fitter Models: F1E******S****
All slip fitter models contain lever nut
connectors inside the junction base to make
appropriate connections.
Conductor Range
0,5-4 mm² [20-12 AWG]
Single Phase Connections
The connections are marked on the terminal
block or on a label and are presented in the
table below.
SYMBOL
COLOR
120-277VAC
GREEN/
YELLOW
N
WHITE
L
BLACK
120-250VDC
GREEN/
YELLOW
N
WHITE
L
BLACK
347-480VAC
GREEN/
YELLOW
L2
RED
L1
BLACK
CONTROLS
DIM +
VIOLET
DIM -
GREY
DALI
ORANGE
DALI
ORANGE
9100FLM00902 REV B
Page 5 of 25
ProSite Floodlight for CE/RCM
0-10 VDC Dimming (If Applicable)
Dimming is controlled by means of a 0-10
VDC signal (to be provided by the installer) to
control the level of dimming. At 10 volts, the
output of the unit is 100%; at 0 volts, the output
will shut off. The DC dimming voltage should
not exceed 15 VDC. Increasing the voltage
from 10 VDC to 15 VDC will not result in
additional light output.
WARNING: Never connect the dimming wires
Strip Length
to the Hot or Neutral supply wires.
9 mm [0,35 in.]
An analog 0-10 V active dimmer may be
connected to the two wires to control the
light output of the fixture. Multiple lights may
be connected to the same dimmer, as long
Strip Length
as the maximum current rating of the dimmer
is not exceeded.
See table for current sinking capabilities of
the
dimmer.
approximately linearly with control voltage,
Strip Length
with 10 V corresponding to 100% light output.
9 mm [0,35 in.]
F1************
F2*****(F/H)******
F2*****(L/N)******
Strip Length
9 mm [0,35 in.]
NOTE: Simply shorting the two wires together
will cause the light to shut off.
CONNECTION
WARNING: Improper installation, operation,
or maintenance of this luminaire may result in
EARTH/
the invalidation of the warranty, certificate,
GROUND
or declaration of conformity.
NEUTRAL
LIVE
EARTH/
GROUND
-
+
EARTH/
GROUND
LIVE 2
LIVE 1
DIMMING +
DIMMING -
DALI
DALI
Variable Voltage Control
Light
output
will
Part Number
Current
0,5 mA
0,5 mA
1,0 mA
Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727
Tel: +1 732 919 3119 Fax: +1 732 751 5778
Maintenance / Inspection
This LED luminaire should require a minimum
amount of maintenance. If any unforeseen
repairs are required, please contact Dialight
or its authorized representative.
Within
the
scope
inspection routine the following should be
included:
 Protective hoses should be covering the
connection cables.
 Cable entries must be free of corrosion.
 The lens should be cleaned periodically as
needed to ensure continued photometric
performance. Clean the lens with a damp,
non-abrasive,
lint
sufficient, use mild soap or a liquid cleaner.
 Inspect the luminaire to ensure that it is free
of any obstructions or contamination (i.e.
vary
excessive dust build up). Clean with a non-
abrasive cloth if needed.
 Perform visual mechanical and electrical
inspections
on
recommend routine checks to be made
on a yearly basis. Frequency of use and
environment should determine this.
It is recommended to follow an Electrical
Preventive
Maintenance
described in NFPA 70B: Recommended
Practice for Electrical Equipment.
Repairs / Overhaul / Modification
The equipment must be operated according
to the intended purpose in a perfect and
undamaged condition.
NOTE: Should the luminaire enclosure be
damaged, only a full luminaire replacement
will be permitted. In case of doubt, the
equipment should be returned to Dialight for
inspection/repair.
Disposal & Recycling
When the apparatus is disposed of, the
respective national regulations on waste
disposal should be observed.