Dialight D1RW-C13-006 Installation And Maintenance Manual

Dual white strobe & red beacon

Advertisement

Quick Links

Document No.
9100-127-1109-99 Rev A
Release Date: SEPT, 11 2007
______________________________________________________________________
INSTALLATION AND MAINTENANCE MANUAL
FOR
P/N: D1RW-C13-006 100-230VAC, 50/60 Hz, (20,000cd
white/2,000cd red beacon)
P/N: D1RW-G13-006 100-230VAC, 50/60 Hz, (20,000cd
white/170cd red beacon)
DUAL WHITE STROBE & RED BEACON
Dialight Corporation 1501 Route 34 South
Farmingdale NJ 07727
Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com
Sheet 1 of 14

Advertisement

Table of Contents
loading

Summary of Contents for Dialight D1RW-C13-006

  • Page 1 Document No. 9100-127-1109-99 Rev A Release Date: SEPT, 11 2007 ______________________________________________________________________ INSTALLATION AND MAINTENANCE MANUAL P/N: D1RW-C13-006 100-230VAC, 50/60 Hz, (20,000cd white/2,000cd red beacon) P/N: D1RW-G13-006 100-230VAC, 50/60 Hz, (20,000cd white/170cd red beacon) DUAL WHITE STROBE & RED BEACON Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com...
  • Page 2: Table Of Contents

    Figure 3: Base - Bottom View ................9 Figure 4: Power/Signal Terminal Arrangement ..........10 Table 1: Troubleshooting ................12 Table 2: Recommended spare parts & user replaceable parts ....13 _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 2 of 14...
  • Page 3: Overview

    Release Date: Sept 11, 2007 _____________________________________________________________________ Overview The Dialight Medium Intensity White Strobe and Red Beacon is designed for the lighting of radio towers, wind generators and other obstructions to aerial navigation. This design uses LED technology for light output both from the Beacon and White Strobe.
  • Page 4 The latter mode is a fail-safe mode of operation. If the fault clears, the fault signal will remain until power to the unit is cycled. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com...
  • Page 5 Day ht Controller Driver Contac Strobe Driver Sync Strobe Dim 0 Driver Dim 1 Fault White Fault Figure 1: Block Diagram _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 5 of 14...
  • Page 6: Installation And Wiring

    Cabinet Control Box Light Engine Power In Multi-way connection cable Control Box to Power Supply Connections Figure 2: System Wiring Diagram _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 6 of 14...
  • Page 7 4: For maximum immunity from the effects of radiated interference, the cable from the Control Box to Power Supply Cabinet should be shielded with the screen grounded at both ends. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 7 of 14...
  • Page 8: Switch Settings

    Power Supply to Light Engine Cable The connection between the power supply and light engine is made by means of a shielded multi-way connection cable. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 8 of 14...
  • Page 9 Release Date: Sept 11, 2007 _____________________________________________________________________ Mounting the Light Engine Dialight recommends the installation of one or more lightning rods near the installed Light Engine. The lightning rods should extend a minimum of three feet above the height of the Beacon.
  • Page 10: Operation And Initial Test

    MOVs and Gas Discharge Tubes (GDTs). It is designed to withstand 6kV/3kA, 1.2/50us, 8/20us Combination Wave Transients as described in IEC61000-4-5. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 10 of 14...
  • Page 11: Maintenance And Troubleshooting

    30 seconds to indicate voltages on capacitors have been discharged to less than 50V. Table 1 Lists possible faults and repair procedures for the light _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 11 of 14...
  • Page 12 Beacon driver driver module and properly. module is lit light engine. Possible LED string failure. Possible LED string Replace light engine. failure. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 12 of 14...
  • Page 13: Table 2: Recommended Spare Parts & User Replaceable Parts

    Dialight Part Number Light Engine Module (2000cd) 8800-865-0017-00 Light Engine Module (170cd) 8800-865-0018-00 Power Supply 8800-865-0067-00 Light Engine to Power Supply Cable 8800-865-0089-00 _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 13 of 14...
  • Page 14: Specifications

    Light Engine Specifications Weight 21.5 kg Height 297.3 mm Diameter 470 mm Bolt Hole down Pattern Standard Pattern provided (See Fig. 3) _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 14 of 14...