Release Date: Sept 11, 2007 _____________________________________________________________________ Overview The Dialight Medium Intensity White Strobe and Red Beacon is designed for the lighting of radio towers, wind generators and other obstructions to aerial navigation. This design uses LED technology for light output both from the Beacon and White Strobe.
Page 4
The latter mode is a fail-safe mode of operation. If the fault clears, the fault signal will remain until power to the unit is cycled. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com...
Page 5
Day ht Controller Driver Contac Strobe Driver Sync Strobe Dim 0 Driver Dim 1 Fault White Fault Figure 1: Block Diagram _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 5 of 14...
Cabinet Control Box Light Engine Power In Multi-way connection cable Control Box to Power Supply Connections Figure 2: System Wiring Diagram _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 6 of 14...
Page 7
4: For maximum immunity from the effects of radiated interference, the cable from the Control Box to Power Supply Cabinet should be shielded with the screen grounded at both ends. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 7 of 14...
Power Supply to Light Engine Cable The connection between the power supply and light engine is made by means of a shielded multi-way connection cable. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 8 of 14...
Page 9
Release Date: Sept 11, 2007 _____________________________________________________________________ Mounting the Light Engine Dialight recommends the installation of one or more lightning rods near the installed Light Engine. The lightning rods should extend a minimum of three feet above the height of the Beacon.
MOVs and Gas Discharge Tubes (GDTs). It is designed to withstand 6kV/3kA, 1.2/50us, 8/20us Combination Wave Transients as described in IEC61000-4-5. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 10 of 14...
30 seconds to indicate voltages on capacitors have been discharged to less than 50V. Table 1 Lists possible faults and repair procedures for the light _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 11 of 14...
Page 12
Beacon driver driver module and properly. module is lit light engine. Possible LED string failure. Possible LED string Replace light engine. failure. _____________________________________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com Sheet 12 of 14...