P1-6. KEY
Panel key is detected.
When the A/D conversion value of the panel key becomes out of the specified range, normal operation will not
be available.
In that case, check the constant of voltage dividing resistor, solder condition, etc. Refer to table.
* When "P1-6. KEY" menu is selected, keys become inoperable due to detection of the values of all keys.
However, it is possible to advance to the next menu by turning the VOLUME knob.
(Reference voltage: 3.3 V=255)
Display
A/D value
Key name
000 – 011
INP+
012 – 034
INP-
035 – 059
TRE+
060 – 083
TRE-
084 – 109
BASS+
110 – 135
BASS-
136 – 161
RTN
162 – 186
ENTER
255
OFF
P1-6
KY:255/255 OFF
KEY0
A/D value
INPUT a
000 – 011
INPUT
012 – 034
TREBLE +
035 – 059
TREBLE –
060 – 083
BASS +
084 – 109
BASS –
110 – 135
RETURN
136 – 161
162 – 186
SELECT
PUSH – ENTER
(jog dial)
187 – 213
̶
214 – 241
Key name
KEY1
KEY0
Display
Key name
TUN+
TUNING
TUN-
TUNING
PST+
PST-
BAND
MEM
MODE
DISP
SPA
SPEAKER A
SPB
SPEAKER B
255
OFF
R-N402/R-N402D
KEY1
PRESET
PRESET
BAND
MEMORY
MODE
DISPLAY
̶