5.8.2

COM log settings

Transmitted data through COM port could be logged for recording or debugging purposes. Addition-
ally, the logs could be reported to an external Syslog server as well. Figure 24 shows the COM Log
Settings page under the Log Settings menu. Description of each option is explained as follows.
Figure 24: COM Log Settings web page under System Setup
• Log Data Contents: If this option is enabled, the COM logging function will log the content's
data that is being transmitted and received in raw bytes. If this option is disabled, COM logging
function will only log the length of data to reduce system load.
N OT I C E
wienet SDS can store up to 100 Kbytes internally. A request or a response will be in one line, and the
data longer than 512 bytes will go into another line. You can retrieve logs by using an FTP Client. The
FTP login is the same as the Web UI login. Logs are located in /var/log/logcomxx (xx is the port num-
ber). When the reserved space is full, new logs will replace old logs. We strongly recommend sending
COM logs to a remote Syslog server.
• Data Types: There are two radio buttons, which are hexadecimal (HEX) and ASCII, to select the
desired logged data's format.
• COM Ports: The user can select which port(s) will be logged by checking the corresponding
boxes.
• Enable Syslog Server: Enabling this option allows the user to send COM logs to a remote Syslog
server. It is possible to send COM logs to the same Syslog server used previously for event log-
ging (see section 5.8.1 System log settings, p. 27).
• IP Address: When the Syslog Server is enabled in the previous option, please specify the remote
Syslog server's IP address in this field.
• Syslog Server Service Port: This option allows user to specify the remote Syslog Server Port
number between 1 and 65535. Note that the default port number is 514.
After finishing the configuration of the COM Log Settings, please click on Save & Apply to keep the
change that you have made and to apply your setting. When the saving and applying are finished,
the web browser will remain on the COM Log Settings page. If you want to cancel the change and
reset all changes back to their original values, just click the Cancel button.