Reverse Osmosis Membrane Replacement

(every three years)
(RO)
a) Use the same procedure as above sec a-c.
b) Remove the RO stage from the clips. Disconnect the white
tubing from the RO housing cap.
c) Remove the cap from the housing by unscrewing it.
d) Using a pair of pliers, remove the RO element from the housing
by grasping the tube end and pulling it out.
e) Use RO filter replacement P/N CSM50 (50gpd CSM membrane).
Insert the element into the housing with double "o"-ring end
going in first–toward the bottom of the housing. Make sure the
"o"-rings are sealed. Replace the cap. Reconnect the white
tubing. Proceed as in above section (g) to (i)
Figure 5. Reverse Osmosis Replacement
13 |