Removal of Coils / Thermistors
Step
3. Remove the thermistors.
Open the putty and
1
remove the liquid pipe
thermistors.
Pull out the gas pipe
2
thermistors.
3
Cut the clamp.
Pull out the outdoor
heat exchanger
thermistor.
26
Procedure
Clamp
Outdoor heat exchanger
thermistor
Points
When reassembling, meet
the edge of the thermistor
and the fixture.
Liquid pipe
thermistor
(R11184)
Gas pipe
thermistor
(R5591)
Be careful not to lose the
clip.
(R17171)
The positions of the clamp
and outdoor heat exchanger
thermistor differ depending
on the model.
Si121174
Clip
(R5619)
Removal Procedure