Designs
Risk of fire through overheating if there are insufficient ventilation clearances
Inadequate ventilation clearances cause overheating with a risk for personnel due to smoke
and fire. Further, increased failures and shorter service life of the devices/systems can occur.
Under all circumstances, maintain a ventilation clearance of 80 mm above and below the NX
module.
An NX can be mounted in the control cabinet in the following ways:
NX on the side of the SINAMICS drive line-up
First, you must insert the supports into the cutouts of the NX that are attached to the Line
Module. Then the NX can be attached to the Line Module.
NX with spacer directly on the rear panel of the control cabinet - standard
The NX is secured with two M6 screws (6 Nm) to the mounting panel.
NX without spacer directly on the rear panel of the control cabinet
In addition, you can secure the NX directly on the rear panel of the control cabinet even without
spacers. Using this method, you must remove the spacer attached as standard when originally
supplied.
Note
The spacer is secured with M3 torx screws on the NX. You require a screwdriver T10 to attach/
remove the spacer.
1. Removing the holding plate.
2. Remove the angle plate.
3. Attach the holding plate to the NX using M3 screws (0.8 Nm).
4. Attach the NX with two M6 screws (6 Nm) to the mounting panel.
Mounting an NX to an additional NX
For stability reasons, you can connect the bracket of one NX to the clip of an adjacent NX:
1. Open the interface covers.
2. Release the screw fixing the bracket.
3. The bracket must be moved so that the pin is in the opening of the bracket. Tighten the screw.
4. Close the interface covers.
NCU 7x0.3B PN
Equipment Manual, 10/2020, 6FC5397-1EP40-6BA1
WARNING
Connectable components
9.1 NX10.3 / NX15.3
93