INSTALLATION OF PRISM® COMPACT (AD2455-1,
AD2455-2, AD2455-5, AD2455-6, & AD2455-9 ONLY)
TOOLS NEEDED
• 5/16" Nutdriver
• 9/16" Nutdriver
• Ladder/Lift
• Drill + 1/4" Drill Bit
Step 1 – Remove The 4X4 Wood Frame
Remove lag bolts and discard 4X4 wood frame.
FIGURE A.1
Step 2 – Install Fan Silencer
Open main door of unit and remove fan silencer (or
discharge grill and rain guard for AD2455-9). Remove it
from the packaging. Install fan silencer using 3/8 inch
bolts (See Figure A.2). For AD2455-9 only, place the
discharge grill on the fan outlet, then place the rain
guard on the discharge grill. Fasten them using 3/8 inch
bolts.
AD2455-1: 10 bolts
AD2455-2: 12 bolts
AD2455-5: 10 bolts
AD2455-6: 12 bolts
AD2455-9: 10 bolts
Wood frame bolted at
bottom of machine frame
(not pictured).
FIGURE A.2
Step 3 – Compressed Air Connection
Connect Compressed air source to tting (ISO 6150 B pro le
- 1/4"). Adjust regulator pressure to 6 bar (87 psi) max.
FIGURE A.3
A-3