LC100
XpressNET DCC Converter
Art. No. 24100
Revised 4/00
The XpressNET DCC Converter LC100
connects input devices from other
manufacturer's NMRA DCC systems
with any XpressNET based system.
This allows reuse or expansion of
other systems with DIGITAL plus.
Any devices that send the standard
NMRA DCC format to the track can be
connected to the LC100.
Submitted to the NMRA for
C&I testing
DIGITAL plus
1

Advertisement

loading

Summary of Contents for Lenz DIGITAL plus LC100

  • Page 1 LC100 XpressNET Converter The XpressNET DCC Converter LC100 connects input devices from other manufacturer's NMRA DCC systems with any XpressNET based system. This allows reuse or expansion of other systems with DIGITAL plus. Any devices that send the standard NMRA DCC format to the track can be connected to the LC100.
  • Page 2 LH200 Handheld, your Tower Cab (LW100) or on the Computer Interface (LI100). The procedure is described in the appropriate manuals. If you need to use 2 LC100 units, they have to be programmed to different addresses. Please contact LENZ for further advice.
  • Page 3 LC100 XpressNET Converter Connecting the LC100 to a "foreign" DCC System The connections to the LC100 are always according to the same principle, independent of the other digital device: The terminals that connect the other digital system to the tracks is connected to the screw terminals labeled "Gleisanschluß...
  • Page 4 LC100 XpressNET Converter Using ROCO and LGB Digital Figure 1 Connecting the LC100 to a ROCO "Digital is Cool" or LGB "Multi Train Control" DCC System Controlling locomotives The locomotives using the addresses 1 to 8 can be moved as usual with the 'loco mouse'.
  • Page 5 LC100 XpressNET Converter Emergency Stop Triggering an emergency stop on the 'loco mouse' leads to a shut down of track voltage on the connected DIGITAL plus System. The LED's on the 'loco mouse' will start to blink, and a message is posted on the Handheld LH100.
  • Page 6: Stop And Go

    LC100 XpressNET Converter in speed and direction, as the settings for speed and direction are stored in the central unit=. A change in direction on a LH100 Handheld is not send to the central unit=. Similarly, none of the auxiliary function settings are send from the LH100 Handheld to the central unit=.
  • Page 7 LC100 XpressNET Converter The central unit= will not know if a NOTAUS or NOTHALT is triggered in the DIGITAL plus system. The LED on the central unit= stays on. If you want to remove the emergency condition from the control 80(f), you have to press first the 'stop' and then the 'go' button on the control 80(f).
  • Page 8: Warranty

    LC100 XpressNET Converter Warranty Lenz GmbH does everything it can do to ensure that its products are free from defects and will operate for the life of your model railroad equipment. From time to time even the best-engineered products fail either due to a faulty part or from accidental mistakes in installation.