Changing the battery

CAUTION!
Using incorrect battery types or incorrectly rated batteries can result in damage to the bat-
tery or devices connected to the electroblock. So therefore:
F
F
F
Normally only batteries of the same type and rating should be used, i.e. the same as those
originally installed by the manufacturer.
It is possible to swap lead-acid batteries with AGM batteries. However, swapping from AGM
batteries to lead-acid batteries is only possible in certain circumstances. Contact the vehicle
manufacturer for further information.
DANGER!
Incorrectly setting the battery selector switch poses a risk of explosion (through the forma-
tion of detonating gas). So therefore:
F
Changing
Electrically isolate the battery from the electroblock -- and perform a shutdown on the IT
"
the battery
... / LT ... operator and control panel (see also Section 4.2).
Isolate the electroblock from the mains.
"
Replace the battery.
"
Fig. 4
Move the battery selector switch (Fig. 4, Pos. 1) to the correct position using a thin object
"
(e.g. a ballpoint pen):
F
F
After changing the battery, check again the type of battery used and then ensure that the
"
battery selector switch is in the correct position.
6
Only have batteries changed by qualified personnel
Follow the battery manufacturer's instructions
Only connect the electroblock to 12V power supplies with rechargeable 6 cell AGM or
lead-acid batteries. Do not use any unsuitable battery types.
Move the battery selector switch to the correct position.
Battery selector switch
AGM battery: Set the battery selector switch to "AGM".
Lead-acid battery: Set the battery selector switch to "Blei-Säure".