TECHNOLOGIES

Protect-or-Disconnect
In the event of a catastrophic surge such as lightning, AC power completely disconnects from connected equipment. If such a rare event occurs, the VT1512-IP would require service.
Standard Level RFI/EMI Filtration
The standard level RFI/EMI filter employs a tuned lowpass filter to reduce the differential AC noise coming through your AC power line. The filter reduces the AC line noise on average 18dB @,
100kHz, 53dB @, 1MHz, 18dB – 53dB @, 100kHz – 1MHz.
Over/Under voltage load disconnect
The Over/Under voltage load disconnect circuit constantly monitors the incoming line voltage. If the incoming line voltage becomes dangerously high, it will disconnect the load from the AC
input. The high threshold is 140 Vac +/- 2 Vac.
If the incoming line voltage becomes dangerously low, it will disconnect the load from the AC input. The low threshold is 85 Vac +/- 2 Vac.
When the incoming voltage returns to a safe level, the VT1512-IP will automatically turn on and sequence to its original state before the Over/Under voltage event.
Power Sequencing
Some complicated audio & video systems will require power sequencing. The VT1512-IP by default is a power sequencer. Power sequencing allows A/V equipment to be powered up in stages
which gives equipment time to stabilize before the next stage of equipment is energized.
When powering down, the sequence order is reversed, which results in a soft landing for your expensive A/V equipment. Power sequencing is also convenient for network devices that requires
network "handshakes" to properly communicate with each other.
After applying power to the AC line input and once you turn the power switch on, outlet 1 will turn on immediately. Outlet 2 will turn on 5 seconds after outlet 1, and all other outlets will have a
5 second delay from the power on time of the previous outlet. See defaults below.
Once you claim your VT1512-IP, you can change the default programing to meet your systems requirements and you have complete flexibility. You can keep a 12-step sequence, or keep four
outlets powered on and the remaining eight to sequence.
IP Monitor and Control
The VT1512-IP can be monitored and controlled via an internal web page for LAN applications, or you can use the BlueBOLT cloud to monitor, control and program your device from anywhere
in the world via your computer or mobile device.
Outlet Sequence Default
Outlet 1
= 0 second turn on delay, 55 second delay off
Outlet 2
= 5 second turn on delay, 50 second delay off
Outlet 3
= 10 second turn on delay, 45 second delay off
Outlet 4
= 15 second turn on delay, 40 second delay off
Outlet 5
= 20 second turn on delay, 35 second delay off
Outlet 6
= 25 second turn on delay, 30 second delay off
Outlet 7
= 30 second turn on delay, 25 second delay off
Outlet 8
= 35 second turn on delay, 20 second delay off
Outlet 9
= 40 second turn on delay, 15 second delay off
Outlet 10
= 45 second turn on delay, 10 second delay off
Outlet 11
= 50 second turn on delay, 5 second delay off
Outlet 12
= 55 second turn on delay, 0 second delay off