EL-IO-200
Amber
Power on / not connected to network

12. Network Connection

The EL-IO-200 is factory set to use DHCP. Connect to a wired network and use the ELAN
Configurator to connect to the IO-200 Extender. Once connected, use Configurator to set
a static IP address or connect via WiFi.

13. Specifications

Connections
RS-232, Null modem configurable - (2) RJ-45 ports
RS-485 - (2) RJ-45 ports
IR Output, (Mono), - 12V DC - (4) 3.5mm ports
Signal Input - (2) Terminal Block Connectors 3-pin
Relay - (2) Terminal Block Connectors 3-pin
Ethernet / PoE IEEE 802.3af (802.3at Type 1) - (1) RJ-45 port
Power (1) Coaxial Type A, 2.5mm inside diameter. 5V 2A
2.4 / 5 GHz WiFi 802.11 b/g/n/ac
System
Software compatibility - Refer to the integration note for compatibility
Updates managed by ELAN Core Module software
General
Operating Temperature - 0° to 40° C
Operating Humidity - 90% Maximum (Non-Condensing)
Mounting - Free standing, Wall mount, Structured wiring cabinet
Product Dimensions 8.46in W x 1.63in H x 5in D / 215mm W x 41.5mm H x 127mm D)
Product Weight 0.8 lb / 0.36 Kg
Certifications - CE, FCC, C-Tick / RCM