Service Connections - Crown GLTS-30 Installation & Operation Manual

Gas power tilt skillets
Hide thumbs Also See for GLTS-30:

Advertisement

S
C
ERVICE
ONNECTIONS
S
ERVICE
- Unless otherwise specified, Field Wire Electrical Connection to
be 120 Volts, 60 Hz, single phase with grounding wire. Unit
furnished with 6' cord and 3 prong plug. Total max amps 4.0.
Model
Capacity
Units
30 Gallons
inches
GLTS-30
(114 liters)
(millimeters)
40 Gallons
inches
GLTS-40
(152 liters)
(millimeters)
Shipping
Model
Weight
550 lbs.
GLTS-30
[249 kg]
736 lbs.
GLTS-40
[334 kg]
* For use on non-combustible floors only.
4
PAGE
OF 16
C
ONNECTIONS

SERVICE CONNECTIONS

A
B
C
36"
33.88"
72.25"
(914 mm)
(860 mm)
(1835 mm)
48"
45.88"
71.75"
(1219 mm)
(1165 mm)
(1822 mm)
GAS CHARACTERISTICS
BTU/HR
kW/HR
80,000
23.4
100,000
29.3
INSTALLATION & OPERATION MANUAL 10100 REV 0 (04/21)
- GAS CONNECTION: Supply gas through 3/4" pipe.
C
- COLD WATER: 3/8" O.D. tubing to optional faucet
H
- HOT WATER: 3/8" O.D. tubing to optional faucet
DIMENSIONS
D
E
F
33.5"
23.5"
39.50"
(851 mm)
(597 mm)
(1003 mm)
43.5"
23"
39.88"
(1105 mm)
(584 mm)
(1013 mm)
Gas Supply
Supply Pipe Pressure (W.C)
Natural
6" - 14"
(152 mm - 356 mm)
(279 mm - 356 mm)
Gas Power Tilt Skillets
G
H
J
4"
6"
3.75"
(102 mm)
(152 mm)
(95 mm)
(1089 mm)
4"
6"
4.75"
(102 mm)
(152 mm)
(121 mm)
(1089 mm)
Minimum Clearance *
Sides
Propane
11" - 14"
Back
K
Ø2
Ø3
42.88"
48.5"
(1232 mm)
42.88"
48.5"
(1232 mm)
3"
(76 mm)
6"
(152 mm)

Advertisement

loading

This manual is also suitable for:

Glts-40