TAbLE OF CONTENTS General Information General I nformation, F eatures, S pecifications ................Page 1 Installation Wall M ount, M eter M ount, P anel M ount ..................Page 2 Connections, F T420 O ption 9 8, - 98 R elay B oard S pecifications ............. Page 3 Connection Diagrams FT415,...
-30˚ t o 6 5˚ C ( -22˚ t o 1 48˚ F ) Environmental NEMA 4 X, I P66 NEMA 4 X, I P66 CE E N 6 1000 CE E N 6 1000 *Specifications subject to change • Please consult our website for current data (www.seametrics.com). Page 1...
INSTALLATION Wall Mount. To mount an FT400-Series indicator to the Meter Mount wall,holdtheunitinthedesiredposition,marktheholes in t he m ounting f eet, d rill a nd m ount w ith s crews. W ith t he Sensor Wires FT420W-65 o ption, fi rst r emove t he f ront c over t o g ain a c- cess...
Page 5
INSTALLATION Connections. T o c onnect t he F T400-Series fl ow c omputer Caution: If output is being used to to a fl ow s ensor o r a n e xternal d evice s uch a s a c hemical control an external device, such as a metering...
CONNECTION DIAGRAMS FT415 Standard Connections Pulse Responsive Metering Pump Caution: Do not apply external power to the FT415. Battery Type: Micropower Lithium "C, 3V, replaceable Sensor Current sinking polarity-sensitive (Passes flow sensor pulse on to White another control without scaling) Black Connections for FT420/3-Wire Mechanical Meter BASIC CONNECTIONS...
Page 7
CONNECTION DIAGRAMS Connections for FT420-98 (Dual Relay Output Option) Electronic NOTE: O utputs m ay b e p aralleled Metering Pumps to s witch u p t o 2 00 m A A C/DC Isolated Contact White Black Flow Sensor Relay Board white wire...
Page 8
CONNECTION DIAGRAMS FT420 Display with 4-20 mA Output When r unning t he F T420 w ith a m agmeter ( which r equires p ower), t he F T420 m ust b e c onnected t o t wo p ower s upplies, o ne f or t he magmeter...
Page 9
Find it on the fitting 00001.000 (80-Series) or chart (100/200-Series) or on the SeaMetrics website. SET K P is the number of gallons per pulse desired on the scalable pulse output. (Example: P=1 is one pulse per gallon.) Skip without changing if you are not...
"locked" t o p revent t ampering. P lease c ontact y our D istributor for a ssistance.) The K-factor on any Seametrics flow sensor fitting or Set P/Flow Alarm. F T420 o nly. A t t his s creen y ou m ay s elect...
OPERATION Resettable/Non-Resettable Totalizer.Unlesstheunithas Operation of the Pulse Output. I f t he p ulse o utput i s b eing been o rdered w ith t he n on-reset o ption, a R ESET p rompt i s used (either standard electronic or relay-type), it should visible...