Trouble Shooting - Mitsubishi Electric PLA-A.EA7 Operation Manual

Split-system heat pump
Hide thumbs Also See for PLA-A.EA7:
Table of Contents

Advertisement

Available languages

Available languages

7. Trou le Shooting
Having trouble?
Air conditioner does not heat or cool well.
When heating operation starts, warm air does not blow from the indoor
unit soon.
During Heat mode, the air conditioner stops before the set room tem-
perature is reached.
set.
A cracking or creaking sound is heard.
The room has an unpleasant odor.
A white mist or vapor is emitted from the indoor unit.
Water or vapor is emitted from the outdoor unit.
"
" appears in the remote controller display.
When restarting the air conditioner soon after stopping it, it does not
operate even though the ON/OFF button is pressed.
Air conditioner operates without the ON/OFF button being pressed.
Air conditioner stops without the ON/OFF button being pressed.
Remote controller timer operation cannot be set.
"PLEASE WAIT" appears in the remote controller display.
An error code appears in the remote controller display.
Draining water or motor rotation sound is heard.
The vanes do not move or the indoor unit does not respond to input from
the wireless remote controller.
Here is the solution. (Unit is operating normally.)
■ Check the temperature adjustment and adjust the set temperature.
■ Make sure that there is plenty of space around the outdoor unit. Is the
indoor unit air intake or outlet blocked?
■ Has a door or window been left open?
up.
■ When the outdoor temperature is low and the humidity is high, frost
may form on the outdoor unit. If this occurs, the outdoor unit performs
a defrosting operation. Normal operation should begin after approxi-
mately 10 minutes.
■ During Heat mode, the vanes automatically move to the horizontal air-
mode.
tion after detecting the base position.
■ These sounds can be heard when parts rub against each due to
expansion and contraction from temperature changes.
■ The indoor unit draws in air that contains gases produced from the
walls, carpeting, and furniture as well as odors trapped in clothing,
and then blows this air back into the room.
■ If the indoor temperature and the humidity are high, this condition may
occur when operation starts.
mist.
■ During Cool mode, water may form and drip from the cool pipes and
joints.
■ During Heat mode, water may form and drip from the heat exchanger.
■ During defrosting mode, water on the heat exchanger evaporates and
water vapor may be emitted.
■ During central control, "
" appears in the remote controller display
and air conditioner operation cannot be started or stopped using the
remote controller.
■ Wait approximately three minutes.
(Operation has stopped to protect the air conditioner.)
■ Is the on timer set?
Press the ON/OFF button to stop operation.
■ Is the air conditioner connected to a central remote controller?
Consult the concerned people who control the air conditioner.
■ Does "
" appear in the remote controller display?
Consult the concerned people who control the air conditioner.
■ Has the auto recovery feature from power failures been set?
Press the ON/OFF button to stop operation.
■ Is the off timer set?
Press the ON/OFF button to restart operation.
■ Is the air conditioner connected to a central remote controller?
Consult the concerned people who control the air conditioner.
■ Does "
" appear in the remote controller display?
Consult the concerned people who control the air conditioner.
■ Are timer settings invalid?
If the timer can be set,
or
display.
■ The initial settings are being performed. Wait approximately 3 min-
utes.
■ The protection devices have operated to protect the air conditioner.
■ Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be
sure to provide the dealer with the model name and information that
appeared in the remote controller display.
■ When cooling operation stops, the drain pump operates and then
stops. Wait approximately 5 minutes.
■ The junction wire connectors of the vane motor and signal receiver
may not be connected correctly. Have an installer check the connec-
tions. (The colors of the male and female sections of the junction wire
connectors must match.)
appears in the remote controller
-