Self-Check Function; Check Of The Iic Bus Lines - Panasonic TH-50PV700AZ Service Manual

Hide thumbs Also See for TH-50PV700AZ:
Table of Contents

Advertisement

9 Self-check Function

Use the self-check function to test the unit.
1. Checking the IIC bus lines
2. Power LED Blinking timing
9.1.

Check of the IIC bus lines

9.1.1.
How to access
Self-check indication only:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control
for more than 3 seconds.
Self-check indication and forced to factory shipment setting:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU] button on the remote
control for more than 3 seconds.
9.1.2.
Screen display
9.1.3.
Check Point
Confirm the following parts if NG was displayed.
9.1.4.
Exit
Disconnect the AC cord from wall outlet.
TH-50PV700AZ / TH-50PV700H / TH-50PV700M / TH-50PV700MR
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-50pv700hTh-50pv700mTh-50pv700mr

Table of Contents