PROGRAMMING THE BREWER (cont.)

ASSIGN RECIPES

This function allows for assigning a coffee name
other than NO-NAME to the BREW switch.
Procedure to assign recipes:
1. Press and hold the upper right hidden switch until
the display reads UNITS. Release the switch, then
press and release switch until the display reads
ASSIGN RECIPE ?.
2. Press YES to assign a recipe to the BREW
switch.
3. Use (-) and (+) to select recipe which you want to
assign to the BREW switch.
4. Press and release DONE when selected to advance
to next function screen, ENABLE ADS.
ASSIGN RECIPE ?
NO
SELECT RECIPE
NO-NAME
(-)
NEXT FUNCTION

ENABLE ADS?

This function allows the operator to choose whether
or not to display the advertising message that was en-
tered into the brewer with an AD CARD. This message
will be displayed when the brewer is not in use.
ENABLE ADS ?
NO
DONE
YES
5 SEC. DELAY
DONE
(+)
EXIT TO
SCREEN
YES
P2721
Procedure to Enable/Disable Ads:
1. Press and hold the upper right hidden switch until
the display reads UNITS. Release the switch, then
press and release switch until the display reads
ENABLE ADS. The YES or NO will be flashing to
indicate the current selection.
2. Press and release the NO switch to disable this
function (no ads will be displayed on the screen),
or;
3. Press and release the YES switch to enable this
function (ads will be displayed on screen).
4. When finished, press and release DONE to save
the new setting, exit the ENABLE ADS function and
advance to the next function screen, SET TEMP.
Another alternative is to press the ON/OFF switch
located on the front switch panel to exit the ENABLE
ADS function and return to the MAIN SCREEN.
P3515
SET TEMP - Range: 185˚F (85˚C) to 205˚F (96˚C)
This function allows the operator to set the brew
water temperature in the tank. It also sets the hot water
faucet dispense temperature.