SERVICE (cont.)
Warmer Switch(es)
RL:
Right Rear Three Heat Rotary
FIG. 14 THREE HEAT WARMER SWITCH
Location:
This switch is the farthest on the right of the base as
viewed from the front, FIG. 14. Its knob is marked
Off/Low/Med/High.
Test Procedure:
1.
Check the voltage across terminals L1 and N with
a voltmeter. Connect the brewer to the power
source. The indication must be:
a) 120 volts ac for two wire 120 volt models and
three wire 120/240 volt models.
b) 200 or 240 volts ac for two wire 200 volt or
240 volt models.
c) 100 volts ac for two wire 100 volt models.
2.
Disconnect the brewer from the power source.
If voltage is present as described, proceed to #3.
If voltage is not present as described, refer to the Wir-
ing Diagrams and check the brewer wiring harness.
3.
Check the voltage across terminals L1 and 3 with
a voltmeter when the switch is in the "Low", "Med",
or "High" positions. Connect the brewer to the
power source. The indication must be as de-
scribed in step 1. Voltage must not be present
across these terminals in the "Off" position.
4.
Disconnect the brewer from the power source.
IN G
R N
W A
ER
RM
!
WA
DR
Y
HE
AT
ER
GH
CA
NT
AY
HI
DE
S AW
S
T BO
IL
TIB
LE
SK
NO
US
LY
RI
D
DO
CO
MB
MP
LIQ
UI
EP
CO
OT
RD
KE
TO
RE
/H
ZA
ILU
RE
ILU
E HA
FA
S FA
FIR
AS
S AN
D
GL
BU
RN
P1713
5.
Check the voltage across terminals L1 and 2 with
a voltmeter when the switch is in the "High" posi-
tion. Connect the brewer to the power source.
The indication must be as described in step 1.
Voltage must not be present across these termi-
nals in the "Off", "Low", or "Med" positions.
6.
Disconnect the brewer from the power source.
7.
Check the voltage across terminals N and 1 with
a voltmeter when the switch is in the "Med" or
"High" positions. Connect the brewer to the power
source. The indication must be as described in
step 1. Voltage must not be present across these
terminals in the "Off" or "Low" positions.
8.
Disconnect the brewer from the power source.
9.
Check the voltage across terminals N and 2 with
a voltmeter when the switch is in the "Low" posi-
tion. Connect the brewer to the power source.
The indication must be as described in step 1.
Voltage must not be present across these termi-
nals in the "Off", "Med", or "High" positions.
10. Disconnect the brewer from the power source.
If voltage is present as described, the switch is oper-
ating properly.
If voltage is not present as described, replace the
switch.
Removal and Replacement:
1.
Remove the knob from the switch.
2.
Loosen the 5/8" nut on the switch shaft and push
the switch through the opening.
3.
Remove the wires from the switch terminals.
4.
Refer to FIG. 15 when reconnecting the wires.
5.
Securely mount the new switch onto the hous-
ing and reinstall the knob.
NOTE: Switch must be installed right side up.
N
1 2
FIG. 15 THREE HEAT WARMER SWITCH WIRING
Page 18
WHI or RED to Terminal Block
WHI or RED to Right Front
Warmer
WHI or RED to Indicator Lamp
L1
RED or BLACK to Terminal
Block
3
RED to Right Rear Warmer
BRN to Right Rear Warmer
WHI to Right Rear Warmer
P1696
10020 111598