Step 1
Desired Operation
Base Time Ranges
0.1s to 1s
0.1s to 3s
Select a time
0.1s to 6s
range that
contains the
0.1s to 10s
desired period
0.3s to 30
of time.
0.6s to 60
1.8s to 180s
6s to 600s
The set time is selected by turning the l Setting Knob.
For information, call 800-221-0487
Instructions: Setting GT3F Series Timers
j Dial Selector
0-1, 0-3, 0-6, 0-18, 0-60
Selection
j Dial Selector
k Time Range Selector
0 to 1
0 to 3
0 to 6
0 to 1
0 to 3
0 to 6
0 to 18
0 to 60
Step 2
Switches Unlimited
USA: 800-262-IDEC
tech@switchesunlimited.com
POWER Indicator
l Setting Knob
k Time Range Selector
1S, 10S
1s
Time range can be selected from 1S and 10S using a fl at screwdriver and fi ve
different dials of 0 to 1, 0 to 3, 0 to 6, 0 to 18, and 0 to 60 are displayed in the six
windows by turning the Dial Selector, allowing for selecting the best suited scale.
Note that the switch does not turn infi nitely.
10s
Setting Examples:
1. When the Setting Knob l is set at 2.5, with Dial Selector j 0 to 3 and Time
Range Selector k 1S selected, then the set time is 2.5 seconds.
2. When the Setting Knob l is set at 5.0,
with Dial Selector j 0 to 60 and Time Range Selector k 10S selected, then the
set time is 500 seconds.