Draining The Hot Water Tank - Bunn FMD-1 Operating & Service Manual

Bunn fmd-1: service manual
Table of Contents

Advertisement

DRAINING THE HOT WATER TANK

CAUTION - The dispenser must be disconnected from the power source throughout these steps.
1.
Disconnect the dispenser from the power source.
2.
Open front door and place tank heater switch in the "OFF" (upper) position.
3.
Shut-off and disconnect the incoming water supply.
4.
Remove the top panel.
5.
Gently remove one of the grommets from the tank lid.
6.
Insert a tube to the bottom of the tank and syphon ALL of the water out.
(Bunn-O-Matic has a syphon assembly #12440.0000 available for this purpose.)
NOTE - The dispenser must be refilled using the INITIAL FILL & HEAT steps before reconnecting to the power
source.
HOPPER DISPENSE RATE OF PRODUCT
1.
Hopper dispense rate with 8 tooth gear and auger wire is approximately 4 to 6 grams per second.
2.
Hopper dispense rate with optional 12 tooth gear and auger wire is 6 to 9 grams per second.