User Notices - Bunn CDBC Operating & Service Manual

Bunn cdbc: user guide
Table of Contents

Advertisement

Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should
be kept in good condition. Replace any unreadable or damaged labels.
#00658.0000
#00831.0000
!
CAUTION
When re-wiring the machine for operation on
120/208V or 120/240V, the replacement Power
Supply Cord must be UL Listed Flexible Cord Type
SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4
Conductor, Rated 90° C. Attachment Plug Cap
must be UL Listed, NEMA 14-20P or L14-20P
Configuration, Rated 125/250V, 20 AMPS. The
Power Supply Cord must be at least 3 feet long
and maximum 6 feet long (measured from Strain
Relief to end of the Attachment Plug Cap.)
#34072.0000

USER NOTICES

Page 3
Optional Field Wiring
120 V, 15.0 A, 1800 W
1PH, 2-Wire, 60HZ
#29710.0005 (3 Warmers)
CDBC(F)-DV BREWERS
Optional Field Wiring
120 V, 12.5 A, 1500 W
1PH, 2-Wire, 60HZ
#29710.0006 (No Warmer)
CDBC(F) APS-DV BREWERS
Optional Field Wiring
120/208-240 V, 15.6-17.5 A, 2980-3850 W
1PH, 3-Wire, 60HZ
#29710.0007 (3 Warmers)
CDBC(F)-DV BREWERS
Optional Field Wiring
120/208-240 V, 13.0-15.0 A, 2680-3550 W
1PH, 3-Wire, 60HZ
#29710.0008
CDBC(F) APS-DV & TC-DV
BREWERS
29707.1 082803

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdbc tcCdbcfCdbcf tcCdbc apsCdbcf aps

Table of Contents