Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should
be kept in good condition. Replace any unreadable or damaged labels.
#00658.0000
#00831.0000
!
CAUTION
When re-wiring the machine for operation on
120/208V or 120/240V, the replacement Power
Supply Cord must be UL Listed Flexible Cord Type
SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4
Conductor, Rated 90° C. Attachment Plug Cap
must be UL Listed, NEMA 14-20P or L14-20P
Configuration, Rated 125/250V, 20 AMPS. The
Power Supply Cord must be at least 3 feet long
and maximum 6 feet long (measured from Strain
Relief to end of the Attachment Plug Cap.)
#34072.0000
USER NOTICES
Page 3
Optional Field Wiring
120 V, 15.0 A, 1800 W
1PH, 2-Wire, 60HZ
#29710.0005 (3 Warmers)
CDBC(F)-DV BREWERS
Optional Field Wiring
120 V, 12.5 A, 1500 W
1PH, 2-Wire, 60HZ
#29710.0006 (No Warmer)
CDBC(F) APS-DV BREWERS
Optional Field Wiring
120/208-240 V, 15.6-17.5 A, 2980-3850 W
1PH, 3-Wire, 60HZ
#29710.0007 (3 Warmers)
CDBC(F)-DV BREWERS
Optional Field Wiring
120/208-240 V, 13.0-15.0 A, 2680-3550 W
1PH, 3-Wire, 60HZ
#29710.0008
CDBC(F) APS-DV & TC-DV
BREWERS
29707.1 082803