SERVICE (cont.)
TANK HEATERS (cont.)
20. Connect the limit thermostat to the front of the tank
assembly.
21. Connect the green wire to the tank mounting
bracket using #8-32 nut.
22. Connect the pink wire to the level probe.
23. Insert the temperature probe through the grom-
met in the tank lid.
24. Install the elbow fitting of the vent hose into the
grommet in the tank lid.
25. On brewers with faucet, connect the outlet water
line of the faucet to the side of the tank and secure
with clamp.
26. Connect the water supply tube from the solenoid
to the bottom of the tank and secure with clamp.
27. Connect the water supply tube from the dispense
valve to the side of the tank and secure with clamp.
28. Refer to the Wiring Diagrams when reconnecting
the tank heater wires.
29. Install access panels and covers and refer to Initial
Set-up for refill and operation.
Page 27
29707.1 082803