MOUNTING
1. Disassemble the diffuser.
2. Pull the power cord through the gasket.
3. Fix the fixture on the surface with screws.
4. Connect the power cord on the terminal correctly.
5. Open the cover and connect the plug of the battery firmly onto the emergency driver,
close the cover.
6. Assemble the diffuser.
Mounting
4
Cable connection
MAINS POWER SUPPLY
Remove wire bridge when externally switched
Uninterrupted mains supply (for emergency backup function)
Emergency mode version

HOW TO REPLACE BATTERY

1. Cut the power supply first.
2. Open the cover.
3. Pull out the plug of batteries from the emergency driver.
4. Screw out the nut.
5. Remove the old battery.
6. Fix the new battery by screwing nut.
7. Connect the plug onto the emergency driver.
8. Record the date of commissioning of the battery
9. Close the cover firmly.