G8264R Rackswitch Specification Sheet - IBM 8202-E4B Manual

Hide thumbs Also See for 8202-E4B:
Table of Contents

Advertisement

Table 135. Electrical
Electrical characteristics
Power requirements
Voltage
Frequency
Maximum thermal output
Phase
Table 136. Environmental and acoustical requirements
Environment/Acoustical
Airflow direction
Temperature, ambient operating
Temperature (fan failure) operating
Temperature, storage
Relative humidity range
(non-condensing)
Maximum altitude
Heat dissipation
Acoustic noise

G8264R RackSwitch specification sheet

Hardware specifications provide detailed information for your IBM BNT RackSwitch, including
dimensions, electrical, power, temperature, environment, and service clearances.
Table 137. Dimensions
Height
44 mm (1.73 in.)
Table 138. Electrical
Electrical characteristics
Power requirements
Voltage
Frequency
Maximum thermal output
Phase
Table 139. Environmental and acoustical requirements
Environment/Acoustical
Airflow direction
Temperature, ambient operating
Temperature (fan failure) operating
Temperature, storage
Relative humidity range
(non-condensing)
72
Site and hardware planning
Operating
Rear-to-front
0°C - 40°C (32°F - 104°F)
0°C - 35°C (32°F - 95°F)
10% - 90% RH
3050 m (10000 ft)
1100 Btu/hr
Less than 65 dB
Width
439 mm (17.3 in.)
Operating
Rear-to-front
0°C - 40°C (32°F - 104°F)
0°C - 35°C (32°F - 95°F)
10% - 90% RH
Properties
275 W
100 - 240 V ac
50 - 60 Hz
938.3 Btu/hr
1
Storage
-40ºC to +85ºC (-40°F to 185°F)
10% - 95% RH
4573 m (15000 ft)
Depth
513 mm (20.2 in.)
Properties
375 W
100 - 240 V ac
50 - 60 Hz
1280 Btu/hr
1
Storage
-40ºC to +85ºC (-40°F to 185°F)
10% - 90% RH
Weight (maximum)
10.5 kg (23.1 lb)

Advertisement

Table of Contents
loading

This manual is also suitable for:

8202-e4c8202-e4d8205-e6b8205-e6c8205-e6d

Table of Contents